June 2013
Volume 54, Issue 15
Free
ARVO Annual Meeting Abstract  |   June 2013
Optical quality metrics predictive of visual acuity for the design of wavefront guided corrections in the presence of dynamic registration uncertainty
Author Affiliations & Notes
  • Yue Shi
    College of Optometry, University of Houston, Houston, TX
  • Raymond Applegate
    College of Optometry, University of Houston, Houston, TX
  • Ayeswarya Ravikumar
    College of Optometry, University of Houston, Houston, TX
  • Harold Bedell
    College of Optometry, University of Houston, Houston, TX
  • Footnotes
    Commercial Relationships Yue Shi, None; Raymond Applegate, University of Houston (P); Ayeswarya Ravikumar, None; Harold Bedell, None
  • Footnotes
    Support None
Investigative Ophthalmology & Visual Science June 2013, Vol.54, 1279. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to Subscribers Only
      Sign In or Create an Account ×
    • Get Citation

      Yue Shi, Raymond Applegate, Ayeswarya Ravikumar, Harold Bedell; Optical quality metrics predictive of visual acuity for the design of wavefront guided corrections in the presence of dynamic registration uncertainty. Invest. Ophthalmol. Vis. Sci. 2013;54(15):1279.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract
 
Purpose
 

When building a wavefront guided contact lens correction for highly aberrated eyes we would like to achieve the best visual acuity given dynamic registration uncertainty. To optimize the design of such a lens correction, it is useful to have optical quality metrics that are highly correlated with and predictive of visual acuity. The purpose here is to find optical quality metrics that are highly correlated with and predictive of acuity given the unusual aberration structures generated by misalignment of wavefront guided corrections.

 
Methods
 

Residual aberrations were generated by allowing 4 correction designs (3 wavefront guided and 1 sphero-cylinder for each eye) to undergo horizontal, vertical and rotary motion with respect to 3 keratoconic eyes (KC) for 2 pupil sizes (4 and 5mm). Then 77 aberrations were selected based on their log visual Strehl with the expectation that they would induce up to at least 5 lines loss of acuity [JOV, 12:1-13, 2012]. The point spread functions of the selected aberrations were convolved with unaberrated logMAR acuity charts to generate blurred charts, which were presented monocularly to 3 normal chart-readers with 20/15 best corrected acuity. For each chart, visual acuity was measured up to 5th letter missed through a 3 mm pupil placed conjugate and centered with the chart-reader’s dilated pupil. The measured change of acuity with respect to the unaberrated chart was regressed against the changes of acuity predicted by 29 optical quality metrics [JOV, 12:1-13, 2012].

 
Results
 

Regression analysis revealed that only 3 of the 29 metrics (Fig.1) predicted change of measured logMAR acuity with a coefficient of determination (R2) of at least 0.9: logNS (R2=0.96), logVSX (R2 =0.96), and logVSMTF (R2=0.90). The slopes of predicted vs. measured change of acuity did not differ significantly from 1 (α=0.05) for 2 of the 3 metrics: logNS (p=0.28, Fig.2) and logVSX (p=0.13, Fig.3).

 
Conclusions
 

One can confidently use logNS or logVSX to design wavefront guided corrections that minimize the impact of registration uncertainty on visual acuity.

 
 
Fig. 1: R2 values of 29 metrics in the regressions.
 
Fig. 1: R2 values of 29 metrics in the regressions.
 
 
Fig. 2&3: Regressions of measured and predicted change of acuity by logNS or logVSX. 3 data symbols: aberrations generated in 3 KC eyes. Error bars: 1 standard deviaiton of measeured change of acuity by 3 chart-readers.
 
Fig. 2&3: Regressions of measured and predicted change of acuity by logNS or logVSX. 3 data symbols: aberrations generated in 3 KC eyes. Error bars: 1 standard deviaiton of measeured change of acuity by 3 chart-readers.
 
Keywords: 754 visual acuity • 574 keratoconus • 630 optical properties  
×
×