April 2014
Volume 55, Issue 13
Free
ARVO Annual Meeting Abstract  |   April 2014
Revisiting corneal storage using an innovative bioreactor
Author Affiliations & Notes
  • Gilles Thuret
    Corneal Graft Biology, Engineering and Imaging Laboratory, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, Saint-Etienne, France
    Institut Universitaire de France, Paris, France
  • Bernard Aurélien
    Corneal Graft Biology, Engineering and Imaging Laboratory, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, Saint-Etienne, France
  • Nicolas Naigeon
    Corneal Graft Biology, Engineering and Imaging Laboratory, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, Saint-Etienne, France
  • Tanguy Nangoum-Fosso
    Corneal Graft Biology, Engineering and Imaging Laboratory, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, Saint-Etienne, France
  • Zhiguo He
    Corneal Graft Biology, Engineering and Imaging Laboratory, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, Saint-Etienne, France
  • Campolmi Nelly
    Corneal Graft Biology, Engineering and Imaging Laboratory, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, Saint-Etienne, France
  • Acquart Sophie
    Eye Bank, French Blood Center, Saint-Etienne, France
  • Fabien Forest
    Corneal Graft Biology, Engineering and Imaging Laboratory, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, Saint-Etienne, France
    Pathology dpt, University Hospital, Saint-Etienne, France
  • Olivier Garraud
    Eye Bank, French Blood Center, Saint-Etienne, France
  • Gain Philippe
    Corneal Graft Biology, Engineering and Imaging Laboratory, EA2521, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, Saint-Etienne, France
  • Footnotes
    Commercial Relationships Gilles Thuret, University Jean Monnet (P); Bernard Aurélien, None; Nicolas Naigeon, None; Tanguy Nangoum-Fosso, None; Zhiguo He, None; Campolmi Nelly, None; Acquart Sophie, University Jean Monnet (P); Fabien Forest, None; Olivier Garraud, None; Gain Philippe, University Jean Monnet (P)
  • Footnotes
    Support None
Investigative Ophthalmology & Visual Science April 2014, Vol.55, 1452. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Gilles Thuret, Bernard Aurélien, Nicolas Naigeon, Tanguy Nangoum-Fosso, Zhiguo He, Campolmi Nelly, Acquart Sophie, Fabien Forest, Olivier Garraud, Gain Philippe; Revisiting corneal storage using an innovative bioreactor. Invest. Ophthalmol. Vis. Sci. 2014;55(13):1452.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: Be it at 4°C in sealed vials or viewing chambers, or in organ-culture at 31°C in sealed vials, two techniques no revisited since 70’, corneal storage is mandatorily accompanied by a significant endothelial cell (EC) death (600x more than during lifetime) and stromal swelling responsible for endothelial folds triggering additional EC death. The absence of intra ocular pressure that constitutes one of the main forces opposed to the naturally hydrophilic stroma plays an important role in this vicious circle that begins with donor death and is prolonged during storage. The restoration of pressure gradient with circulation of fluids during long-term storage may reduce stromal swelling, posterior folding and consequently improve EC survival. Aim: to present an innovative corneal bioreactor that restores both parameters.

Methods: Review of the literature and of patents on methods available to achieve ex vivo restoration of the corneal physiology and personal works of our laboratory of bioengineering with a patented corneal bioreactor (N°1250832, U25-B-30444 FR).

Results: Several devices have been published or patented previously but none with the aim of improving storage (generally for short-term toxicologic studies) and none using the technical solutions that we developed. Restoration of an increased pressure at the endothelial side associated with a continuous renewal of storage medium allowed rapidly reduction of stromal swelling and improvement of EC viability, compared to the rustic immersion in a sealed flask or viewing chambers.

Conclusions: Our innovative corneal bioreactor can be used for research studies as well as for corneal storage in eye banks.

Keywords: 483 cornea: storage • 481 cornea: endothelium • 741 transplantation  
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×