April 2014
Volume 55, Issue 13
Free
ARVO Annual Meeting Abstract  |   April 2014
Mechanisms of Glaucoma Drug Response Variations: Description of a Multi-Center Study of Aqueous Humor Dynamic Phenotypes
Author Affiliations & Notes
  • Sayoko Eileen Moroi
    Ophthalmology & Visual Sciences, Univ of Michigan-Kellogg Eye Ctr, Ann Arbor, MI
  • Diana Burnett
    Ophthalmology & Visual Sciences, Univ of Michigan-Kellogg Eye Ctr, Ann Arbor, MI
  • Jesse Gilbert
    Ophthalmology & Visual Sciences, Univ of Michigan-Kellogg Eye Ctr, Ann Arbor, MI
  • David M Reed
    Ophthalmology & Visual Sciences, Univ of Michigan-Kellogg Eye Ctr, Ann Arbor, MI
  • Arthur J Sit
    Ophthalmology, Mayo Clinic, Rochester, MN
  • Jay W McLaren
    Ophthalmology, Mayo Clinic, Rochester, MN
  • Vikas Gulati
    Ophthalmology & Visual Sciences, Univ of Nebraska Medical Center, Omaha, NE
  • Donna G Neely
    Ophthalmology & Visual Sciences, Univ of Nebraska Medical Center, Omaha, NE
  • Carol B Toris
    Ophthalmology & Visual Sciences, Univ of Nebraska Medical Center, Omaha, NE
  • David C Musch
    Ophthalmology & Visual Sciences, Univ of Michigan-Kellogg Eye Ctr, Ann Arbor, MI
  • Footnotes
    Commercial Relationships Sayoko Moroi, NIH (F); Diana Burnett, None; Jesse Gilbert, None; David Reed, None; Arthur Sit, AcuMEMS, Inc. (C), Allergan, Inc. (C), Glaukos Corp. (C), Glaukos Corp. (F), Sensimed (C), Sucampo Pharmaceuticals, Inc. (C); Jay McLaren, None; Vikas Gulati, None; Donna Neely, None; Carol Toris, None; David Musch, None
  • Footnotes
    Support None
Investigative Ophthalmology & Visual Science April 2014, Vol.55, 150. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Sayoko Eileen Moroi, Diana Burnett, Jesse Gilbert, David M Reed, Arthur J Sit, Jay W McLaren, Vikas Gulati, Donna G Neely, Carol B Toris, David C Musch; Mechanisms of Glaucoma Drug Response Variations: Description of a Multi-Center Study of Aqueous Humor Dynamic Phenotypes. Invest. Ophthalmol. Vis. Sci. 2014;55(13):150.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: We describe preliminary measurements of a new study designed to test the hypothesis that individual aqueous humor dynamic (AHD) variables can predict a patient’s glaucoma medication response.

Methods: Our prospective, randomized clinical trial aims to determine AHD phenotypes in patients with glaucoma and normal subjects at the University of Michigan, University of Nebraska, and Mayo Clinic. In 8 visits, we will measure intraocular pressure (IOP; iCare, Ocular Response Analyzer® (ORA®), Goldmann applanation, and pneumatonometry), biometry, cataract (Lens Opacities Classification System III, LOCS), aqueous humor flow rate, episcleral venous pressure, and outflow facility before and after treatment with timolol 0.5%, and latanoprost 0.005%. Physical measurements, medical history, and physical activity will be determined by using PhenX Toolkit, version 4. To date, we examined relationships among lens autofluorescence, age, central corneal thickness (CCT), topical anesthetic, and IOP. Relationships were examined by Spearman’s rank correlation (ρ) and Wilcoxon signed rank tests.

Results: We examined 26 healthy subjects with a mean age of 56 ± 12 years. This sample was limited to low grades of cataract (LOCS classification >90% NO1-2, C1-3, and P1-2). Both anterior and posterior lens autofluorescence increased with age (ρ=0.75, p=0.019 and ρ=0.82, p=0.003 respectively) while lens transmittance decreased with age (ρ=-0.67, p=0.048). CCT was correlated between eyes (ρ=0.96). High CCT was associated with high IOP when measured by using iCare (ρ=0.44, p=0.034) and Goldmann applanation tonometers (ρ=0.46, p=0.028), but there was no relationship between CCT and IOP when measured by pneumatonometry (ρ=0.23) or the ORA® (ρ=0.35). There was no difference in IOP as measured by iCare or ORA® with or without proparacaine.

Conclusions: Our multi-center study provides a mechanism to explore ocular physiology. Our preliminary results suggest that, in normal subjects, lens autofluorescence increases and transmittance decreases with age. IOP is not influenced by CCT when measured by pneumatonometry or ORA® or by the use of topical anesthetic when measured by iCare or ORA®. These preliminary measurements will be the basis of our study to explore the relationship between AHD phenotypes and variations in response to glaucoma medications.

Keywords: 427 aqueous • 466 clinical (human) or epidemiologic studies: treatment/prevention assessment/controlled clinical trials • 568 intraocular pressure  
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×