June 2017
Volume 58, Issue 8
Open Access
ARVO Annual Meeting Abstract  |   June 2017
Comparison of postoperative surface light scattering in various hydrophobic acrylic intraocular lenses
Author Affiliations & Notes
  • Jonghyun Lee
    Department of Ophthalmology, Ilsan Paik Hospital, Inje University, Goyang, Gyung-gi-do, Korea (the Republic of)
  • Do hyung Lee
    Department of Ophthalmology, Ilsan Paik Hospital, Inje University, Goyang, Gyung-gi-do, Korea (the Republic of)
  • Jin Hyoung Kim
    Department of Ophthalmology, Ilsan Paik Hospital, Inje University, Goyang, Gyung-gi-do, Korea (the Republic of)
  • Hun Jin Choi
    Department of Ophthalmology, Ilsan Paik Hospital, Inje University, Goyang, Gyung-gi-do, Korea (the Republic of)
  • Footnotes
    Commercial Relationships   Jonghyun Lee, None; Do hyung Lee, None; Jin Hyoung Kim, None; Hun Jin Choi, None
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science June 2017, Vol.58, 2726. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to Subscribers Only
      Sign In or Create an Account ×
    • Get Citation

      Jonghyun Lee, Do hyung Lee, Jin Hyoung Kim, Hun Jin Choi; Comparison of postoperative surface light scattering in various hydrophobic acrylic intraocular lenses. Invest. Ophthalmol. Vis. Sci. 2017;58(8):2726.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : To evaluate the long-term change in surface light scattering of several hydrophobic acrylic intraocular lenses (IOLs) and the clinical importance of these findings.

Methods : A total 160 eyes of 96 patients who underwent cataract surgery with implantation of a hydrophobic acrylic IOL were enrolled in this study. Patients were divided into two groups according to the IOL manufacturer: Acrysof IOL (MA60BM, SA60AT, SN60WF; Alcon, Inc.) and Sensar or Tecnis IOLs (AR40e, ZA9003, ZCB00; Abbot Medical Optics, Inc.). The surface light scattering was measured by area densitometry using a Scheimpflug camera (EAS-1000, NIDEK, Aichi, Japan).

Results : The anterior and posterior surface light scattering in the Acrysof IOLs steadily increased up to 10 years postoperatively (r = 0.870, p < 0.001 and r = 0.855, p < 0.001, respectively). The intensity of anterior and posterior surface light scattering in the Acrysof IOLs was significantly greater than that in the Sensor or Tecnis IOLs (p < 0.05), except the posterior surface light scattering during 1 to 2 years postoperatively.

Conclusions : Surface light scattering of Acrysof hydrophobic acrylic IOLs gradually increases postoperatively as time progresses. As the surface light scattering of IOLs increases, Neodymium:YAG (Nd:YAG) laser posterior capsulotomy typically becomes more difficult to perform. In cases of posterior capsule opacification (PCO) in Acrysof IOLs, laser posterior capsulotomy should be considered earlier than in the typical case.

This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017.

×
×