Microscopic lateral imaging with adaptive optics makes AOSLO uniquely able to determine, in vivo, the spatial origin of the intrinsic retinal signal. This is accomplished by comparing the spatially resolved poststimulus and prestimulus ratio image, pixel by pixel, with the corresponding intensity image of the cone mosaic. Pixel values in the ratio image, as opposed to a difference image, are independent of the corresponding pixel values in the intensity image; therefore, any correlations between the two images will reveal true functional correlations and not artifacts. Our comparisons of the ratio image to the prestimulated intensity images show that the signal comes primarily from the cones, though not all cones respond equally. Confirmation of the fact that our signal originates from cones is provided by plotting each pixel’s intensity values from the intensity image (showing retinal structure) against the corresponding pixel values from the ratio image (showing intrinsic signals;
Fig. 4 ). Pixels of higher intensity in the prestimulated intensity image correspond to cones. If larger intrinsic responses come from the brighter regions of the image, it follows that the intrinsic signals must also originate from the cones or be wave guided through them. This is indeed what we found. The largest signal changes, coming from the individual cones, were approximately 20%. Plotting pixel-by-pixel values rather than cone-by-cone values avoided artifacts that might have been introduced by assumptions made in cone identification.
Sophisticated image stabilization software to remove eye movements was required for our analysis to give valid results because any small error in image stabilization on the single cone scale would generate “cone shadow” artifacts across the ratio image that would outweigh true signal and average changes to zero. Precise image stabilization is especially important in an SLO system, where eye movements cause intraframe distortions and interframe shifts. Our stabilization software corrected the intraframe distortions in narrow horizontal strips and has been demonstrated to correct to a single cone scale.
20 21
Although the axial resolution of AOSLO is large compared with OCT, we could also determine the axial origin of the intrinsic signal. A confocal pinhole was selected that provided axial resolution of approximately 150 μm. By imposing defocus on the deformable mirror, we stepped through a range of retinal layers with the AOSLO
(Fig. 5) .
22 23 Movies were recorded with best focus on the photoreceptors, below the photoreceptors extending into the choroid, above the photoreceptors on the inner retinal layers, and on the nerve fiber layer.
Table 2shows the results. In 2 of 2 subjects, the change in intensity ratio was highest at the plane of best focus on the photoreceptors.
The signal we detected represented the total percentage reflectance change integrated within the axial resolution profile illustrated in
Figure 5 . Our results have polarity and time courses similar to those measured with OCT, but the magnitudes are different. However, the differences between AOSLO and OCT intrinsic signal magnitudes are attributed not only to differences in axial resolution but also to the different mechanisms by which the scattered signal was recorded. An AOSLO images features in the retina by raster scanning a focused spot on the retina, which is imaged again though a confocal pinhole. Axial and lateral image resolution is limited by diffraction, whereas OCT axial resolution is limited by the coherence length of the light source. The important difference occurs with the photoreceptors, where the light is wave guided and emerges from the inner segments at the location of the external limiting membrane. Although little light actually scatters from that layer, the AOSLO signal detects the combination of all wave-guided reflections as though they are originating from that surface. OCT reveals that the sources of wave-guided light originate from the inner/outer segment junction and from the outermost tip of the outer segment (Gao W, et al.
IOVS 2007;48:ARVO E-Abstract 3849). Therefore, the intensity of photoreceptors in the AOSLO image is a sum of the signal from the outer segments, the inner-outer segment junction, and the inner segment tips. The AOSLO axial section also includes scattered light from every other layer that falls under the axial resolution profile, such as the outer nuclear layers, the retinal pigment epithelium, and the choroid, where signal decreases may occur because of blood flow contributions, but these are weighted by the axial resolution profile
(Fig. 5) . As such, we expected our changes to be smaller than those of OCT because our changes combined sources with negative and positive intrinsic signals and were measured relative to the intensity of prestimulated images that integrate reflectance from a much thicker axial section, much of which has no intrinsic signal.
With the use of OCT in excised rabbit retina, Bizheva et al.
7 found positive intrinsic signals of up to 80% over a time course of seconds originating in the outer segments and negative intrinsic signals of 30% with a similar time course in the inner segments, for a combined change of approximately 50%. OCT in living rat found an approximately 25% near infrared reflectance increase in response to visible light stimulation that was largely confined to the outer segment.
8 OCT measurements of the intrinsic signal magnitude, integrated over the whole photoreceptor, were up to one order of magnitude higher than our results, with the same polarity and similar time course. Compared with results obtained with fundus imaging (Tso DY, et al.
IOVS 2007;48:ARVO E-Abstract 1951),
2 3 4 5 6 our signals are almost one order of magnitude larger and are of opposite polarity, though of similar time course. Recent studies have shown that the negative polarity signals detected with fundus imaging methods result from blood flow in the choroid (Tso DY, et al. IOVS 2007;48:ARVO E-Abstract 1951). In fundus imaging systems with no depth discrimination, the negative choroidal blood flow signal combines with the positive retinal signal, most often yielding small negative responses but sometimes also yielding positive responses.
2 6 Because of the depth resolution of AOSLO, our results tend to agree more with those obtained with OCT
7 8 than with fundus imaging.
The correlation of the signal with the stimulus form was highest in the photoreceptors and decreased at other layers, even though an intrinsic signal was present
(Table 2) . This confirms the notion that the signal is initiated by the excitation of the light-sensitive photoreceptors, where the response will necessarily correlate with the stimulus pattern. By the time the visual signals activate various other neural layers, some of the retinotopy will be lost, and the consequent spatial correlation with the stimulus will decrease. With OCT, signals have also been detected in upper retinal layers in in vitro rabbit retina, particularly the inner plexiform layer, where a signal increase of approximately 25% was seen, though with a slower rise to maximum response (5 seconds).
7
It has been suggested that the origin of the retinal intrinsic signal could be ion flux, cell swelling and shrinking, membrane hyperpolarization, or structural changes in the outer segment disks, though many of these factors are known to occur on a time scale shorter than that of the observed signals.
9 Our results
(Fig. 2)demonstrated that the increased scatter occurred within the cone and not between the cones. An unexpected advantage of this finding is that the contrast of the cone mosaic is actually increased by the presence of an intrinsic signal. However, the origin of the signal in other layers was less well defined; the cells were not visualized by conventional AOSLO because of their relative transparency.
Changes in absorption caused by photobleaching cannot affect the intrinsic signal directly given that the absorption of all the photopigments is essentially zero at the 840-nm imaging wavelength. However, secondary nonabsorptive changes as a result of photobleaching cannot be ruled out. If secondary scattering changes as a result of photobleaching were the source of the signal, we would have expected to detect signal selectively from L-cones because they were preferentially bleached by the stimulus light. Changes in scattering caused by photobleaching were not likely, however, considering the following three observations: intrinsic signals of similar magnitude and time course were observed for dimmer stimuli, where significantly less photobleaching occurred; intrinsic signals often returned to baseline within seconds after the stimulus, whereas the generation of new photopigment after a bleach had a longer time course; the nature of the intrinsic signals we observed was variable between subjects and from day to day in single subjects. Photopigment bleaching and regeneration dynamics, on the other hand, are stable and predictable.
24