January 1983
Volume 24, Issue 1
Free
Articles  |   January 1983
The use of vitreous fluorophotometry to distinguish between diabetics with and without observable retinopathy: effect of vitreous abnormalities on the measurement.
Investigative Ophthalmology & Visual Science January 1983, Vol.24, 57-65. doi:
  • Views
  • PDF
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      T C Prager, H H Chu, C A Garcia, R E Anderson, J B Field, E A Orzeck, J P Comstock; The use of vitreous fluorophotometry to distinguish between diabetics with and without observable retinopathy: effect of vitreous abnormalities on the measurement.. Invest. Ophthalmol. Vis. Sci. 1983;24(1):57-65.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
This content is PDF only. Please click on the PDF icon to access.
Abstract

Ten age-matched normals, diabetics with retinopathy, and diabetics without observable retinopathy were evaluated by vitreous fluorophotometry (VFL) using a 0.15 mm and a 0.45 fiberoptic probe in a photomultiplier system as well as a commercially available photodiode instrument to determine whether differences in intraocular sodium fluorescein levels could be detected among the three groups. Each subject was injected in the antecubital vein with 7 mg/kg of sodium fluorescein (25% solution) and measurements were taken 1 hr postinjection at 4.5 mm and 7.5 mm from the retina. The influence of choroidal fluorescein and ocular pigmentation are reduced at these locations. We found that a breakdown in the blood-ocular barrier may not be present early in the course of diabetes. Furthermore, no significant difference was found between normals and diabetics without retinopathy. Although the mean value for vitreous fluorescein was significantly higher in diabetics with retinopathy compared to normals, several of the diabetics with retinopathy had values in the normal range. These results differ from those previously reported in the literature. However, our studies took into consideration several factors not considered by other investigators, such as ocular pigmentation, choroidal fluorescence, slit width, and vitreous changes, that may have significant effects on the fluorophotometry values.

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×