Noninvasive measurement of rat intraocular pressure with the Tono-Pen.
Author Affiliations
  • C G Moore
    Casey Eye Institute, Oregon Health, Sciences University, Portland 97201.
  • S T Milne
    Casey Eye Institute, Oregon Health, Sciences University, Portland 97201.
  • J C Morrison
    Casey Eye Institute, Oregon Health, Sciences University, Portland 97201.
Investigative Ophthalmology & Visual Science February 1993, Vol.34, 363-369. doi:
  • Views
  • PDF
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      C G Moore, S T Milne, J C Morrison; Noninvasive measurement of rat intraocular pressure with the Tono-Pen.. Invest. Ophthalmol. Vis. Sci. 1993;34(2):363-369.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
This content is PDF only. Please click on the PDF icon to access.
Abstract

PURPOSE: The purpose of this study was to evaluate the Tono-Pen 2 tonometer for measuring intraocular pressure (IOP) in the living rat eye. METHODS: One eye from each of 20 adult, anesthetized brown Norway rats (group 1) was cannulated and simultaneously connected to a syringe and a pressure transducer with a chart recorder. We increased IOP from 15 to 45 mmHg in 5-mmHg increments and obtained 15 consecutive readings (ignoring instrument-generated averages) at each pressure increment with a Tono-Pen 2 tonometer. To test the tonopen's ability to measure unknown IOP, transducer pressures were varied randomly in 20 additional animals (group 2), and tonopen readings were obtained in masked fashion. RESULTS: Plotting the mean tonopen readings for each animal against transducer IOP produced a regression formula of y = 4.54 + 0.79x (r = 0.98). Mean group 2 tonopen values plotted against transducer IOP yielded a regression formula of y = 4.75 + 0.78x (r = 0.94). A method comparison analysis showed that the tonopen significantly overestimates pressures at low IOP (< or = 15 mmHg), and it significantly underestimates pressures at high IOP (> or = 30 mmHg). Using two-way analysis of variance, it was determined that the group 2 data did not differ significantly from the group 1 data (P > or = 0.76). Because of this consistency, we generated a correction factor with 95% prediction intervals for Tono-Pen readings. CONCLUSIONS: The Tono-Pen 2 can be used reliably to measure IOP in the normal rat eye.

×
×