May 1996
Volume 37, Issue 6
Free
Articles  |   May 1996
A new method for determining corneal epithelial barrier to fluorescein in humans.
Author Affiliations
  • A Joshi
    Allergan Incorporated, Irvine, California 92715, USA.
  • D Maurice
    Allergan Incorporated, Irvine, California 92715, USA.
  • J R Paugh
    Allergan Incorporated, Irvine, California 92715, USA.
Investigative Ophthalmology & Visual Science May 1996, Vol.37, 1008-1016. doi:
  • Views
  • PDF
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      A Joshi, D Maurice, J R Paugh; A new method for determining corneal epithelial barrier to fluorescein in humans.. Invest. Ophthalmol. Vis. Sci. 1996;37(6):1008-1016.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
This content is PDF only. Please click on the PDF icon to access.
Abstract

PURPOSE: To derive the value of corneal epithelial barrier to fluorescein in humans from experiments in which the fluorophore in instilled in a single drop. METHOD: A commercial scanning fluorophotometer, the Fluorotron Master, was used to scan through an anterior segment. It could not resolve the tear film from the cornea, but in the early stages of measurement, the tear component predominated. After 20 minutes, the remaining fluorescein was washed out of conjunctival sac, and the amount that penetrated into the cornea was estimated. Because the resolution was not sufficient to estimate the concentrations, the total masses in the tear film and in the cornea derived from the area under the profile were used to calculate the epithelial permeability. A value for the tear film thickness had to be assumed. RESULTS: The technique led to reproducible values for epithelial permeability-a range of 2:1 in a subject. High concentrations of fluorescein were required to achieve a sufficient penetration into the cornea, and this led to error in estimating the tear film concentration of the dye. A method is presented that corrects for this effect. For 17 normal subjects, the corrected permeability was 0.15 nm/second, and the tear turnover was 0.15/minute ( +/- 0.016, standard error.) CONCLUSIONS: This technique is convenient and yields two useful physiological parameters from a single clinical procedure. The permeability values are considerably higher than those found by previous workers, and the source of the discrepancy is discussed.

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×