February 1999
Volume 40, Issue 2
Free
Articles  |   February 1999
In vivo human corneal hydration control dynamics: a new model.
Author Affiliations
  • M T Odenthal
    The Department of Ophthalmology, Academic Medical Center, Amsterdam, The Netherlands.
  • C P Nieuwendaal
    The Department of Ophthalmology, Academic Medical Center, Amsterdam, The Netherlands.
  • H W Venema
    The Department of Ophthalmology, Academic Medical Center, Amsterdam, The Netherlands.
  • J Oosting
    The Department of Ophthalmology, Academic Medical Center, Amsterdam, The Netherlands.
  • J H Kok
    The Department of Ophthalmology, Academic Medical Center, Amsterdam, The Netherlands.
  • A Kijlstra
    The Department of Ophthalmology, Academic Medical Center, Amsterdam, The Netherlands.
Investigative Ophthalmology & Visual Science February 1999, Vol.40, 312-319. doi:
  • Views
  • PDF
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      M T Odenthal, C P Nieuwendaal, H W Venema, J Oosting, J H Kok, A Kijlstra; In vivo human corneal hydration control dynamics: a new model.. Invest. Ophthalmol. Vis. Sci. 1999;40(2):312-319.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
This content is PDF only. Please click on the PDF icon to access.
Abstract

PURPOSE: To introduce a new model describing human in vivo corneal deswelling after hypoxic contact lens wear, based on a damped harmonic oscillator, which can describe an overshoot in corneal deswelling, to compare this new model with the currently used exponential model, and also to test whether a diurnal variation in baseline corneal thickness exists that would have to be taken into consideration when calculating corneal deswelling curves. METHODS: In nine healthy young adults, corneal thickness was measured every 30 minutes for 11.5 hours on average using modified optical pachometry (natural test). On another day, corneal deswelling was monitored for 11.1 hours on average after 2 hours of hypoxic contact lens wear (stress test). The damped harmonic oscillator model and the exponential model were used to calculate best-fitting deswelling curves. Natural test data were analyzed for the presence of a trend. Goodness of fit of the curves to the experimental data was analyzed using the F test. RESULTS: In 82% of the deswelling curves the new damped harmonic oscillator model provided a better fit to the data than the exponential model (P < 0.05). An average overshoot in corneal thickness recovery of 5 microm (range, 0-11 microm) was found. In 50% of the natural tests significant trends were found, without any consistent similarities. The overshoot could not be explained by these trends. CONCLUSIONS: The new damped harmonic oscillator model describes corneal deswelling after hypoxic contact lens wear more accurately than the exponential model. No consistent diurnal variation could be demonstrated.

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×