Noninvasive assessment of the hydration gradient across the cornea using confocal Raman spectroscopy.
Author Affiliations
  • N J Bauer
    Department of Ophthalmology and Visual Sciences, University of Texas Medical Branch, Galveston 77555-0456, USA.
  • J P Wicksted
    Department of Ophthalmology and Visual Sciences, University of Texas Medical Branch, Galveston 77555-0456, USA.
  • F H Jongsma
    Department of Ophthalmology and Visual Sciences, University of Texas Medical Branch, Galveston 77555-0456, USA.
  • W F March
    Department of Ophthalmology and Visual Sciences, University of Texas Medical Branch, Galveston 77555-0456, USA.
  • F Hendrikse
    Department of Ophthalmology and Visual Sciences, University of Texas Medical Branch, Galveston 77555-0456, USA.
  • M Motamedi
    Department of Ophthalmology and Visual Sciences, University of Texas Medical Branch, Galveston 77555-0456, USA.
Investigative Ophthalmology & Visual Science April 1998, Vol.39, 831-835. doi:
  • Views
  • PDF
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      N J Bauer, J P Wicksted, F H Jongsma, W F March, F Hendrikse, M Motamedi; Noninvasive assessment of the hydration gradient across the cornea using confocal Raman spectroscopy.. Invest. Ophthalmol. Vis. Sci. 1998;39(5):831-835.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
This content is PDF only. Please click on the PDF icon to access.
Abstract

PURPOSE: The feasibility of Raman spectroscopy for the noninvasive assessment of axial corneal hydration was investigated. METHODS: A scanning confocal Raman spectroscopy system, with an axial resolution of 50 microns, was used to assess noninvasively the water (OH-bond) to protein (CH-bond) ratio as a measure of the hydration in collagen-based phantom media and rabbit corneas. RESULTS: Raman spectra with high signal-to-noise ratios were obtained under in vitro and in vivo conditions within a range of corneal hydration (H = 0.0-8.3 mg water/mg dry wt). The Raman intensity ratio OH/CH showed a strong correlation with the hydration of the phantom medium (R2 > 0.99) and the rabbit corneas (R2 > 0.95). A degree of reproducibility was seen in measurements performed at a specific depth within the cornea (SD = 1.2%-2.7%). Quantitatively, the spatially resolved corneal water content, as assessed with our method, showed an increasing gradient from the anterior to the posterior region, with a difference of approximately 0.9. Significant qualitative differences in the axial hydration gradient were observed between the in vitro and in vivo situation, caused by the presence of an intact tear-film in vivo. Characterization of the axial corneal hydration using Raman spectroscopy provided a reliable estimation of total corneal hydration compared with conventional measurements using pachymetry and lyophilization. CONCLUSIONS: The proposed noninvasive confocal Raman spectroscopic technique has the potential to assess the axial corneal water gradient with a degree of sensitivity and reproducibility.

×
×