Investigative Ophthalmology & Visual Science Cover Image for Volume 53, Issue 2
February 2012
Volume 53, Issue 2
Free
Letters to the Editor  |   February 2012
Author Response: Bayesian Estimation of Sensitivity of Temporal Artery Biopsies
Author Affiliations & Notes
  • Ryan D. Niederkohr
    The Permanente Medical Group, Santa Clara, California;
  • Leonard A. Levin
    Department of Ophthalmology and Visual Science, University of Wisconsin, Madison, Wisconsin; and
    Department of Ophthalmology, University of Montreal, Montreal, Canada.
Investigative Ophthalmology & Visual Science February 2012, Vol.53, 586. doi:https://doi.org/10.1167/iovs.11-9361
  • Views
  • PDF
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Ryan D. Niederkohr, Leonard A. Levin; Author Response: Bayesian Estimation of Sensitivity of Temporal Artery Biopsies. Invest. Ophthalmol. Vis. Sci. 2012;53(2):586. https://doi.org/10.1167/iovs.11-9361.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
We thank Stamey and colleagues 1 for their comments on our article. 2 We are in complete agreement that appropriate statistical methodology is important in clinical medicine. The alternative statistical approach they provided is robust in its ability to account for potential conditional dependence (although this parameter is difficult to quantify in the clinical setting). The similarity of results between our approach and their alternative technique is striking. It would be interesting to see whether similar results were yielded by applying the authors' alternative analysis to the other three data sets discussed in our original paper. Most important, we would like to reaffirm that both approaches confirm that the true sensitivity of a temporal artery biopsy is substantially lower than 100%. This is critical in the context of clinical practice because this supposed “gold standard” test is imperfect and can frequently yield falsely negative results. 
References
Stamey J Beavers D Seaman JIII . Bayesian estimation of sensitivity of temporal artery biopsies. E-letter available at http://www.iovs.org/content/48/2/675/reply#iovs_el_9605 .
Niederkohr RD Levin LA . A Bayesian analysis of the true sensitivity of a temporal artery biopsy. Invest Ophthalmol Vis Sci. 2007;48:675–680. [CrossRef] [PubMed]
×
×