April 2014
Volume 55, Issue 13
Free
ARVO Annual Meeting Abstract  |   April 2014
Visual function assessment of patients with early diabetic macular edema using M-charts, Amsler test, “white on white” and “blue on yellow” perimetry
Author Affiliations & Notes
  • Katarzyna Nowomiejska
    Department of General Ophthalmology, Medical University in Lublin, Lublin, Poland
  • Agnieszka Oleszczuk
    Department of General Ophthalmology, Medical University in Lublin, Lublin, Poland
  • Justyna Mazur-Samela
    Department of Ophthalmology, F. Chopin Specialised Hospital, Rzeszow, Poland
  • Robert Rejdak
    Department of General Ophthalmology, Medical University in Lublin, Lublin, Poland
    Centre of Ophthalmology, Institute for Ophthalmic Research, University of Tuebingen, Tuebingen, Germany
  • Footnotes
    Commercial Relationships Katarzyna Nowomiejska, Allergan (R); Agnieszka Oleszczuk, None; Justyna Mazur-Samela, None; Robert Rejdak, None
  • Footnotes
    Support None
Investigative Ophthalmology & Visual Science April 2014, Vol.55, 2291. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Katarzyna Nowomiejska, Agnieszka Oleszczuk, Justyna Mazur-Samela, Robert Rejdak; Visual function assessment of patients with early diabetic macular edema using M-charts, Amsler test, “white on white” and “blue on yellow” perimetry. Invest. Ophthalmol. Vis. Sci. 2014;55(13):2291.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: To detect abnormality of the visual function in patients with early diabetic macular oedema using M-charts, Amsler test and white on white (w/w) and blue on yellow (b/y) perimetry.

Methods: Conventional w/w perimetry and b/y perimetry were performed in the central 10° of the visual field in 24 patients (mean age 52 years, mean visual acuity 0.7) diagnosed with diabetic macular oedema and clear optic media. To assess metamorphopsia- Amsler test and M-charts were used.

Results: Mean sensitivity in b/y perimetry was 17.2 dB and 25.9 dB in w/w perimetry, mean defect 8.9 dB and 3.6 dB and loss variance 4.8 dB and 3.3 dB, respectively (p<0.0001). Mean vertical metamorphopsia score was 0.11°, mean horizontal metamorphopsia score was 0.16°. The rate of detection metamorphopsia was 29% for Amsler test and 41% with M-charts

Conclusions: The mean sensitivity is lower, mean deviation and loss variance higher in b/y in comparison to w/w perimetry. M-chart is more sensitive than Amsler test method for evaluating metamorphopsia. B/y perimetry and M-charts detect earlier than conventional methods the visual function loss in early diabetic maculopathy.

Keywords: 499 diabetic retinopathy • 642 perimetry • 758 visual fields  
×
×