Evaluation of retrobulbar blood flow velocity using colour Doppler imaging: influence of different operators and devices
Author Affiliations & Notes
  • Alice Chandra Verticchio Vercellin
    Eye Clinic, University of Pavia, Pavia, Italy
    Fondazione I.R.C.C.S. Policlinico San Matteo, Pavia, Italy
  • Giovanni Milano
    Eye Clinic, University of Pavia, Pavia, Italy
    Fondazione I.R.C.C.S. Policlinico San Matteo, Pavia, Italy
  • Carlo Alberto Cutolo
    Eye Clinic, University of Pavia, Pavia, Italy
  • Carolina Dellafiore
    Fondazione I.R.C.C.S. Policlinico San Matteo, Pavia, Italy
    Institute of Radiology, Fondazione I.R.C.C.S. Policlinico San Matteo, Pavia, Italy
  • Massimiliano Lava
    Fondazione I.R.C.C.S. Policlinico San Matteo, Pavia, Italy
    Institute of Radiology, Fondazione I.R.C.C.S. Policlinico San Matteo, Pavia, Italy
  • Pietro Distante
    Eye Clinic, University of Pavia, Pavia, Italy
  • Sara Lombardo
    Eye Clinic, University of Pavia, Pavia, Italy
    Fondazione I.R.C.C.S. Policlinico San Matteo, Pavia, Italy
  • Sara Lanteri
    Eye Clinic, University of Pavia, Pavia, Italy
    Fondazione I.R.C.C.S. Policlinico San Matteo, Pavia, Italy
  • Carmine Tinelli
    Fondazione I.R.C.C.S. Policlinico San Matteo, Pavia, Italy
  • Fabrizio Calliada
    Fondazione I.R.C.C.S. Policlinico San Matteo, Pavia, Italy
    Institute of Radiology, Fondazione I.R.C.C.S. Policlinico San Matteo, Pavia, Italy
  • Footnotes
    Commercial Relationships Alice Chandra Verticchio Vercellin, None; Giovanni Milano, None; Carlo Alberto Cutolo, None; Carolina Dellafiore, None; Massimiliano Lava, None; Pietro Distante, None; Sara Lombardo, None; Sara Lanteri, None; Carmine Tinelli, None; Fabrizio Calliada, None
  • Footnotes
    Support None
Investigative Ophthalmology & Visual Science April 2014, Vol.55, 2933. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Alice Chandra Verticchio Vercellin, Giovanni Milano, Carlo Alberto Cutolo, Carolina Dellafiore, Massimiliano Lava, Pietro Distante, Sara Lombardo, Sara Lanteri, Carmine Tinelli, Fabrizio Calliada; Evaluation of retrobulbar blood flow velocity using colour Doppler imaging: influence of different operators and devices. Invest. Ophthalmol. Vis. Sci. 2014;55(13):2933.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: To evaluate the inter-device reproducibility of retrobulbar blood flow measurements obtained by two commercially available colour Doppler imaging (CDI) devices.

Methods: The right eyes of 10 healthy volunteers were investigated. Four examiners, namely two ophthalmologists and two radiologists, performed CDI examination of the ophthalmic artery, central retinal artery and temporal short posterior ciliary arteries using both CDI devices: ESAOTE MYLAB™ (probe LA533 13-6 MHz small parts-vascular linear array) and SIEMENS ANTARES STELLAR PLUS™ (probe VFX 9-4 MHz vascular linear array). The peak systolic, the end-diastolic velocities, and the resulting resistivity index were averaged for 3 cardiac cycles. In order to evaluate the reproducibility between both device measurements, the Lin’s concordance correlation coefficient (CCC) was used. CCC can be expressed as the product of Pearson's r (the measure of precision) and C_b (the measure of accuracy).

Results: Results show that the inter-device reproducibility for CDI measurements is not acceptable since a poor degree of overall concordance (0.15<CCC<0.37) was obtained: accuracy was high (C_b > 0.71) but overall precision low (0.18< Pearson’s r <0.47). Ophthalmologists and radiologists obtained similar results.

Conclusions: In order to evaluate the causal role of blood flow abnormalities in glaucoma, CDI analysis using different devices seems unreliable. CDI inter-device reproducibility seems unrelated to medical speciality of the examiners. However, in order to improve present results, the use of similar probes and standardized CDI instrument settings as well as a CDI images analysis by a single grader, might possibly improve the inter-device reproducibility when testing the retrobulbar blood flow velocity.

Keywords: 552 imaging methods (CT, FA, ICG, MRI, OCT, RTA, SLO, ultrasound)  
×
×