Repeatability of Measurements from Fourier-Domain OCT for Detecting Ectatic Diseases of Corneal Epithelial Thickness
Author Affiliations & Notes
  • Ana Laura Caiado Canedo
    Cornea & Refrative Surgery, Rio de Janeiro Corneal Tomography & Biomechanics Study Group, Rio de Janeiro, Brazil
  • Bruno F Valbon
    Cornea & Refrative Surgery, Rio de Janeiro Corneal Tomography & Biomechanics Study Group, Rio de Janeiro, Brazil
  • Rosane Correa
    Cornea & Refrative Surgery, Rio de Janeiro Corneal Tomography & Biomechanics Study Group, Rio de Janeiro, Brazil
  • Renato Ambrosio
    Cornea & Refrative Surgery, Rio de Janeiro Corneal Tomography & Biomechanics Study Group, Rio de Janeiro, Brazil
  • Footnotes
    Commercial Relationships Ana Laura Canedo, None; Bruno Valbon, None; Rosane Correa, None; Renato Ambrosio, Oculus (C)
  • Footnotes
    Support None
Investigative Ophthalmology & Visual Science April 2014, Vol.55, 5544. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Ana Laura Caiado Canedo, Bruno F Valbon, Rosane Correa, Renato Ambrosio; Repeatability of Measurements from Fourier-Domain OCT for Detecting Ectatic Diseases of Corneal Epithelial Thickness. Invest. Ophthalmol. Vis. Sci. 2014;55(13):5544.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: To evaluate the repeatability of corneal epithelial thickness measurements from Fourier domain optical coherent tomography (FD-OCT; RTVue, Optovue, Fremont, CA) on normal, forme fruste keratoconus (FFKC) and keratoconus (KC).

Methods: One eye randomly selected from 10 normal and from 10 keratoconus patients, and from 10 eyes with forme fruste keratoconus were included. FFKC criteria was the fellow eye with normal topography from patients with very asymmetric keratoconus. The minimum, maximum, central, superior and inferior epithelial thickness values were computed for the central 6mm zone. For each eye, 5 consecutive measurements were taken by the same observer using the RTVue. The standard deviation (repeatability [SD]) and coefficient of variation (CV [SD divided by average]) of the 5 consecutive measurements taken for each parameter.

Results: The repeatability (SD) for the normal, keratocons and FFKC groups were respectively: 1.19, 2.22 and 0.752 for minimal; 0.742, 1.175 and 1.595 for maximal; 0.639, 1.6 and 1.166 for central; 0.71, 0.879 and 0.846 for superior; 0.627, 1.161 and 0.907 for inferior; and 0.322, 0.306 and 0.415 for the variation of epithelial values. The CV for the normal, keratocons and FFKC groups were respectively (%): 2.838, 5.893 and 1.626 for minimal; 1.295, 1.894 and 2.761 for maximal; 1.224, 3.199 and 2.245 for central; 1.412, 1.6 and 1.631 for superior; 1.206, 2.285 and 1.743 for inferior.

Conclusions: OCT RTVue was found to be very precise with less than 2 microns of repeatability for minimum, maximum, central, superior and inferior corneal epithelial thickness values on the central 6mm zone. Corneal epithelial measurements should be tested for their accuracy for detecting ectatic diseases.

Keywords: 482 cornea: epithelium • 574 keratoconus • 552 imaging methods (CT, FA, ICG, MRI, OCT, RTA, SLO, ultrasound)  
×
×