Development of a novel head-mounted perimeter - Measuring the visual field of both eyes by showing the target alternately and randomly to each eye -
Author Affiliations & Notes
  • Sayaka Yamao
    Department of Ophthalmology, Kinki University Faculty of Medicine, Osakasayama, Japan, Osakasayama, Japan
  • Chota Matsumoto
    Department of Ophthalmology, Kinki University Faculty of Medicine, Osakasayama, Japan, Osakasayama, Japan
  • Hiroki Nomoto
    Department of Ophthalmology, Kinki University Faculty of Medicine, Osakasayama, Japan, Osakasayama, Japan
  • Fumi Tanabe
    Department of Ophthalmology, Kinki University Faculty of Medicine, Osakasayama, Japan, Osakasayama, Japan
  • Shigeki Hashimoto
    Department of Ophthalmology, Kinki University Faculty of Medicine, Osakasayama, Japan, Osakasayama, Japan
  • Sachiko Okuyama
    Department of Ophthalmology, Kinki University Faculty of Medicine, Osakasayama, Japan, Osakasayama, Japan
  • Yoshikazu Shimomura
    Department of Ophthalmology, Kinki University Faculty of Medicine, Osakasayama, Japan, Osakasayama, Japan
  • Shinji Kimura
    CREWT Medical Systems, Inc., Tokyo, Japan
  • Kenzou Yamanaka
    CREWT Medical Systems, Inc., Tokyo, Japan
  • Makoto Aihara
    Shirato Eye Clinic, Tokyo, Japan
  • Footnotes
    Commercial Relationships Sayaka Yamao, CREWT Medical Systems, Inc. (F); Chota Matsumoto, CREWT Medical Systems, Inc. (F); Hiroki Nomoto, CREWT Medical Systems, Inc. (F); Fumi Tanabe, CREWT Medical Systems, Inc. (F); Shigeki Hashimoto, CREWT Medical Systems, Inc. (F); Sachiko Okuyama, CREWT Medical Systems, Inc. (F); Yoshikazu Shimomura, CREWT Medical Systems, Inc. (F); Shinji Kimura, CREWT Medical Systems, Inc. (E), CREWT Medical Systems, Inc. (P); Kenzou Yamanaka, CREWT Medical Systems, Inc. (E), CREWT Medical Systems, Inc. (P); Makoto Aihara, CREWT Medical Systems, Inc. (C)
  • Footnotes
    Support None
Investigative Ophthalmology & Visual Science June 2015, Vol.56, 1038. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Sayaka Yamao, Chota Matsumoto, Hiroki Nomoto, Fumi Tanabe, Shigeki Hashimoto, Sachiko Okuyama, Yoshikazu Shimomura, Shinji Kimura, Kenzou Yamanaka, Makoto Aihara; Development of a novel head-mounted perimeter - Measuring the visual field of both eyes by showing the target alternately and randomly to each eye -. Invest. Ophthalmol. Vis. Sci. 2015;56(7 ):1038.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: We developed a head-mounted perimeter with a transmissive liquid crystal display for each eye that presents targets separately and randomly to the right and left eyes. One of its features is that it can measure the visual field concurrently with both eyes open. This study was designed to compare the visual field sensitivity of monocular and binocular perimetry using the head-mounted perimeter.

Methods: We can measure the visual field wherever we like as the perimeter is a head-mounted type. Its dimensions are W190 × D380 × H220 mm and weight is 1.6 kg. The target is presented on a transmissive liquid crystal display with high intensity LED backlight. Maximum brightness of the target is 10000 asb and backlight brightness is 31.4 asb. The target can be shown in an arbitrary size and form within 35° from the central visual field. We used Bayesian estimate and adaptive measurement of maximum-likelihood estimate as a threshold measurement algorithm. During the measurement, we can continuously monitor both eyes and each visual fixation. The location of the target is adjusted each time fixation disparity occurs. We can measure the visual field in both eyes at one concurrent examination by showing the target alternately and randomly to each eye without the subject being aware of which eye is tested. This study enrolled 11 normal subjects (age, 35.9 ± 7.18). All the subjects underwent both monocular and binocular perimetry using the head-mounted perimeter. The subjects were also checked if they noticed which eye was tested. We weighed the sensitivity in all the individual measurement points in monocular and binocular perimetry.

Results: The mean sensitivity with monocular perimetry for the right and left eyes were 30.3 ± 4.02 dB and 30.4 ± 3.69 dB, respectively and that with binocular perimetry for right and left were 30.6 ± 3.14 dB and 30.3 ± 3.32 dB, respectively. There was no statistically significant difference in all the individual measurement points (P < 0.05). In addition, all the subjects could not recognize which eye was tested.

Conclusions: The head-mounted perimeter enables us to measure the visual field in both eyes concurrently with the same precision as monocular perimetry while the subject is unaware of which eye is tested. This could contribute to the diagnosis of feigned blindness.

×
×