Visual acuity evaluation with refractions prescribed by a novel low-cost wavefront aberrometer
Author Affiliations & Notes
  • Eduardo Lage
    M+Vision Consortium, MIT, Cambridge, MA
    Plenoptika Inc., Allston, MA
  • Elena Garcia
    Department of Ophthalmology, Fundacion Jimenez Diaz, Madrid, Spain
  • Shivang Dave
    M+Vision Consortium, MIT, Cambridge, MA
    Plenoptika Inc., Allston, MA
  • Maria C. Ramirez
    Department of Ophthalmology, Fundacion Jimenez Diaz, Madrid, Spain
  • Lara M Garcia
    Department of Ophthalmology, Fundacion Jimenez Diaz, Madrid, Spain
  • Nicolás Alejandre Alba
    Department of Ophthalmology, Fundacion Jimenez Diaz, Madrid, Spain
  • Daryl Lim
    M+Vision Consortium, MIT, Cambridge, MA
    Plenoptika Inc., Allston, MA
  • Carlos Dorronsoro
    Instituto de Optica, CSIC, Madrid, Spain
  • Susana Marcos
    Instituto de Optica, CSIC, Madrid, Spain
  • Nicholas Durr
    M+Vision Consortium, MIT, Cambridge, MA
    Plenoptika Inc., Allston, MA
  • Footnotes
    Commercial Relationships Eduardo Lage, MIT (P), Plenoptika, Inc. (S); Elena Garcia, None; Shivang Dave, MIT (P), Plenoptika, Inc. (E); Maria C. Ramirez, None; Lara M Garcia, None; Nicolás Alejandre Alba, None; Daryl Lim, MIT (P), Plenoptika, Inc. (S); Carlos Dorronsoro, MIT (P); Susana Marcos, MIT (P); Nicholas Durr, MIT (P), Plenoptika, Inc. (E)
  • Footnotes
    Support None
Investigative Ophthalmology & Visual Science June 2015, Vol.56, 3570. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Eduardo Lage, Elena Garcia, Shivang Dave, Maria C. Ramirez, Lara M Garcia, Nicolás Alejandre Alba, Daryl Lim, Carlos Dorronsoro, Susana Marcos, Nicholas Durr; Visual acuity evaluation with refractions prescribed by a novel low-cost wavefront aberrometer. Invest. Ophthalmol. Vis. Sci. 2015;56(7 ):3570.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: To compare the visual acuity (VA) resulting from eyeglasses prescribed by a novel autorefractor and by subjective refraction.

Methods: A total of 81 eyes from 42 patients (mean age 38 ± 13yrs, ametropia range -6.25 to +4.5D spherical equivalent power (SE)) were refracted and their VA tested in a clinical setting (Fundacion Jimenez Diaz, Madrid). Refractions were obtained following a standard non-cycloplegic subjective method and with a second generation autorefractor prototype which is handheld, open-view and binocular. This device is based on a simplified approach to wavefront sensing that does not use a Badal relay lens system. The autorefractor is composed of inexpensive off-the-shelf parts including a 1.3-MP CMOS sensor, a 19-mm focal length lenslet array and an 850-nm laser diode. The subjects hold and look through the device while a dynamic sequence of wavefront images is acquired. This dataset is processed using a custom-developed algorithm that tracks patient-device alignment and accommodation to generate a set of measurements from which the prescription is calculated. Three 10-s videos were recorded for each eye and the results of the two last measurements were averaged to calculate the refraction. VA was measured for prescriptions provided by each method and differences between refraction measurements and VA achieved in each case were evaluated.

Results: The average difference between SE measured subjectively and with the prototype was 0.32 ± 0.35D. Refractions obtained from either method were not statistically different (p= 0.96, paired t-test) with a 95% confidence interval of ± 1.0D. The spherical power measured subjectively and with the prototype agreed within 0.25D and 0.5D in 60.5% and 79.0% of the eyes, respectively, while the cylindrical power agreed in 84.0% and 96.4% of the cases for the same thresholds. The average VA achieved with the device and by subjective prescriptions was of 0.000 ± 0.067 and -0.012 ± 0.035 logMar, respectively. Using the prototype refraction, 81.5% of the eyes achieved VA ≥ 20/20 and 98.7% ≥ 20/25.

Conclusions: The new prototype provided accurate measurements of refractive errors in a community optometry clinic. Average discrepancies between VA achieved with the device and subjective refraction were smaller than 0.02 logMar (one letter). A low-cost device, such as the one evaluated here, may be beneficial for improving eye care in low-resource settings.

×
×