June 2015
Volume 56, Issue 7
Free
ARVO Annual Meeting Abstract  |   June 2015
Description and Validation of a new tool for measurement of pigment epithelium detachment (PED) volume: ReVA (Retina Volume Analyzer).
Author Affiliations & Notes
  • Oudy Semoun
    CHI de Creteil, Creteil, France
  • Eric H Souied
    CHI de Creteil, Creteil, France
  • Violaine Caillaux
    CHI de Creteil, Creteil, France
  • Bruno Lay
    ADCIS, Saint-Contest, France
  • Camille Jung
    CHI de Creteil, Creteil, France
  • Rocio Blanco-Garavito
    CHI de Creteil, Creteil, France
  • Footnotes
    Commercial Relationships Oudy Semoun, None; Eric Souied, ADCIS (P); Violaine Caillaux, None; Bruno Lay, ADCIS (P), ADCIS (P); Camille Jung, None; Rocio Blanco-Garavito, None
  • Footnotes
    Support None
Investigative Ophthalmology & Visual Science June 2015, Vol.56, 5945. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Oudy Semoun, Eric H Souied, Violaine Caillaux, Bruno Lay, Camille Jung, Rocio Blanco-Garavito; Description and Validation of a new tool for measurement of pigment epithelium detachment (PED) volume: ReVA (Retina Volume Analyzer).. Invest. Ophthalmol. Vis. Sci. 2015;56(7 ):5945.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: Retinal thickness and volume analysis by Optical Coherence Tomography has recently become a reliable way of monitoring macular disease activity. Nevertheless, retinal volume can consist of several separate anatomical sections that can vary independently and cannot always be analyzed as a whole. We aim to describe and validate the first results of PED volume quantification by a new software (ReVA) and the follow up results after anti VEGF treatment.

Methods: We included in a prospective fashion patients presenting with vascularized PEDs secondary to exudative AMD, previously diagnosed on the basis of multimodal imaging. All patients had undergone complete ophthalmological examination, fluorangiography and ICG angiography. Spectral Domain Optical Coherence Tomography (SD-OCT) on Enhanced Depth Imaging (EDI) mode (Spectralis HRA+OCT, Heidelberg Engineering GmbH, Heidelberg, Germany) was performed, with an acquisition of a 30 degree retinal volume scan consisting of 61 lines centered on the fovea with an averaging of 9 frames per scan. This information was exported in .XML format to the ReVA software. The information was anonymized. A semi automatic analysis of PED volume was perfomed by three independant readers (OS, VC, RBG), twice, at the beginning and end of a 15 day period. The software allows for semi automated demarcation of PED limits on a two dimesional scan basis, and afterwards calculations are peformed to present PED volume results in cubic millimeters. The results are presented in a 3D volume representation that can be manipulated to be seen from various angles. The Bland Altmann assessment for agreement was used to compare intra and inter-observer observations.

Results: We included 20 eyes of 20 patients presenting with vascularize PED. The Bland-Altman analysis indicates that the 95% limits of agreement between the inter and intra observer measures ranged in average from -0.99 to 1.00 with an average correlation of 0.99.

Conclusions: ReVA analyzer is a reliable tool that can assist in the analysis of PED volume with high precision. This type of separate retinal volume analysis can be of help for monitoring disease activity and therapeutic response in AMD.

×
×