Abstract
Purpose:
To explore alternative experimental protocols to investigate the biomechanical behavior of the crystalline lens and zonules using ex-vivo stretching.
Methods:
Radial stretching tests were conducted on the anterior segment (consisting of lens, zonules, ciliary body and sclera) of four pairs of presbyopic human donor eyes. A simple mechanical model is used to describe the behavior of the anterior segment when tested in this way. Each pair of samples was initially stretched with the ciliary body intact. One sample was re-tested after cutting the ciliary body radially and the other sample was re-tested after removing the lens.
Results:
The external forces needed to stretch the sample with the ciliary body intact were significantly greater than for the tests in which the ciliary body had been cut. The forces measured with the ciliary body intact and lens in-situ, were comparable to the sum of the forces measured in the tests where the ciliary body had been cut (lens in-situ) and the forces measured in the tests on the intact ciliary body, with the lens removed.
Conclusions:
When stretching tests are conducted on the anterior segment, significant circumferential tensions develop in the ciliary body. This means that the forces applied to the lens and zonules cannot be related directly to the forces applied by the external loading system. If radial cuts are introduced in the ciliary body prior to testing, however, then this difficulty does not arise.