Effect of Ocular Magnification on Retinal Nerve Fibre Layer Thickness Measurements in Fourier-Domain Optical Coherence Tomography
Author Affiliations & Notes
  • Federico Di Matteo
    Glaucoma Theme, NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
    Ophthalmology, University Vita-Salute, Scientific Institute San Raffaele, Milano, Italy
  • Julia Lamparter
    Glaucoma Theme, NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
    Ophthalmology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
  • Ryo Asaoka
    Glaucoma Theme, NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
  • Richard Russell
    Glaucoma Theme, NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
  • Tuan A. Ho
    Glaucoma Theme, NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
  • David F. Garway-Heath
    Glaucoma Theme, NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
  • Footnotes
    Commercial Relationships  Federico Di Matteo, None; Julia Lamparter, None; Ryo Asaoka, None; Richard Russell, None; Tuan A. Ho, None; David F. Garway-Heath, Carl Zeiss Meditec (F, C, R), Heidelberg Engineering (F, R), Optovue (F)
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science April 2011, Vol.52, 169. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Federico Di Matteo, Julia Lamparter, Ryo Asaoka, Richard Russell, Tuan A. Ho, David F. Garway-Heath; Effect of Ocular Magnification on Retinal Nerve Fibre Layer Thickness Measurements in Fourier-Domain Optical Coherence Tomography. Invest. Ophthalmol. Vis. Sci. 2011;52(14):169.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: : Commercial optical coherence tomography (OCT) devices measure the RNFL at a fixed angular distance from the disc centre. Consequently, the actual distance is greater in myopic eyes. Current models to correct for ocular magnification assume that the retinal nerve fibre layer (RNFL) cross-sectional area (CSA) under different circular scans is constant. The aim of this study is to investigate the relationship between CSA and scan radius as measured by FD-OCT, and to develop a new model to assess the impact of the magnification effect on RNFL thickness measurements.

Methods: : We measured the RNFL thickness along six circles (diameters: 4, 3.7, 3.4, 3.1, 2.8, 2.5 mm) in 31 eyes of 19 healthy volunteers using the RTVue NHM4 scan protocol. Actual scan diameters were corrected using the Bennett's method. Multilevel regression of RNFL CSA with corrected scan diameters was used to impute the value of RNFL thickness at the actual 3.45 mm.

Results: : A significant correlation between 360º CSA and scan radius was found, both in the uncorrected (multilevel regression coefficient: 54, CI 24-84) and magnification-corrected (multilevel regression coefficient: 57, CI: 34-86) analyses. The CSA under each scan arc showed a significant positive correlation with radius in the superior, temporal and inferior quadrants, and a negative correlation in the nasal quadrant. The mean difference between uncorrected (107 µm) and imputed 360º RNFL thickness at the corrected 3.45 mm distance (104.6 µm) was 1.3% (range 8.4 to -9.5%).

Conclusions: : Our results are not consistent with the hypothesis that the CSA under different circles is constant. The overall effect upon the estimation of RNFL thickness at the 3.45 mm scan diameter is relatively small in this unselected sample of healthy subjects. The effect at the extremes of refractive error (and axial length) is more likely to be clinically significant.

Keywords: imaging methods (CT, FA, ICG, MRI, OCT, RTA, SLO, ultrasound) • optic disc • myopia 
×
×