April 2011
Volume 52, Issue 14
Free
ARVO Annual Meeting Abstract  |   April 2011
Aries: Alconfocal Rapid Image Evaluation System of Corneal Microstructure
Author Affiliations & Notes
  • Christine W. Sindt
    Ophthalmology, University of Iowa, Iowa City, Iowa
  • Bruno Lay
    Advanced Concepts in Imaging Software, Herouville Saint-Clair, France
  • Jami R. Kern
    Global Medical Affairs, R & D, Alcon Research Ltd, Fort Worth, Texas
  • Footnotes
    Commercial Relationships  Christine W. Sindt, Alcon (P); Bruno Lay, Alcon (P); Jami R. Kern, Alcon (E)
  • Footnotes
    Support  Alocn
Investigative Ophthalmology & Visual Science April 2011, Vol.52, 1748. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Christine W. Sindt, Bruno Lay, Jami R. Kern; Aries: Alconfocal Rapid Image Evaluation System of Corneal Microstructure. Invest. Ophthalmol. Vis. Sci. 2011;52(14):1748.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: : In vivo confocal microscopy yields images that are useful for evaluating corneal health, but the images contain substantial information that is difficult to analyze. This project was designed to develop robust, rapid, and objective image processing techniques that would facilitate the quantitation of changes in corneal microstructure.

Methods: : From an image database of normal subjects who had consented to scans with a HRT Rostock Corneal Module (Heidelberg), the investigators selected 10 representative scans to develop ARIES. Each scan had at least 40 images, which were 80 µm deep and in 2 µm increments through the central cornea. ARIES was designed to automatically extract and quantify wing and dendritic immune cells and compare to manual analyses. The software also identifies the most prominent nerve section and automatically registers the surrounding sections and reconstructs and displays the nerve plexus in the 3D space. Additional scans (>390) from the database were used for software validation.

Results: : Within 15 seconds, ARIES provides more reproducible, accurate, and comprehensive results than manual assessments. Automated analyses offer several additional parameters that are not practical with manual analysis, including average cell size, proximity to nerves, and shape factors (surface area, perimeter, circularity, diameter, etc). In the case of complex images, a post-processing capability is available to refine the automated results. Unlike manual analyses, ARIES generates a 3D image of the nerve plexus and provides quantitative data including the length, orientation, and number of nerve branches. All data is easily exported for statistical analysis.

Conclusions: : ARIES provides researchers and clinicians with tools to objectively and rapidly quantify changes in corneal health parameters related to epithelial cells, immune cells, and nerves. These advances may facilitate evaluations of the efficacy of a corneal treatment or the progression of a corneal disorder.

Keywords: image processing • cornea: clinical science • imaging/image analysis: clinical 
×
×