April 2011
Volume 52, Issue 14
Free
ARVO Annual Meeting Abstract  |   April 2011
Visual Simulation Of Binocular Depth Of Focus With A Corneal Small Aperture Inlay
Author Affiliations & Notes
  • Christina Schwarz
    Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
  • Juan Tabernero
    Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
  • Enrique J. Fernandez
    Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
  • Pablo Artal
    Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
  • Footnotes
    Commercial Relationships  Christina Schwarz, None; Juan Tabernero, None; Enrique J. Fernandez, None; Pablo Artal, AcuFocus (C)
  • Footnotes
    Support  Ministerio de Educación y Ciencia, Spain (grants nº FIS2007-64765) and "Fundación Séneca", Murcia, Spain (grant 04524/GERM/06)
Investigative Ophthalmology & Visual Science April 2011, Vol.52, 4773. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Christina Schwarz, Juan Tabernero, Enrique J. Fernandez, Pablo Artal; Visual Simulation Of Binocular Depth Of Focus With A Corneal Small Aperture Inlay. Invest. Ophthalmol. Vis. Sci. 2011;52(14):4773.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: : To investigate binocular visual acuity, depth of focus and the mechanisms of binocular summation when one eye forms images through a pupil aperture of 4 mm in diameter and the other eye through a small pupil of 1.5 mm in diameter.

Methods: : We used a binocular adaptive optics visual simulator (Fernández, Prieto & Artal, Opt. Lett. 34, 2628, 2009) to measure both monocular and binocular visual acuity as a function of object vergence. The instrument allows for modifying the magnitude and phase of the eye’s complex pupil function. Three subjects were tested under specially simulated visual conditions: right eyes had "small aperture" vision through a 1.5 mm-diameter pupil and left eyes had normal vision through a 4 mm-diameter pupil. The measurements were performed in photopic and mesopic conditions (placing a neutral density filter with optical density 1.5).

Results: : For the small aperture, we found an increase in binocular and monocular depth of focus compared to the case of 4 mm-diameter pupil. It ranged from 1 to 1.5 D depending on the threshold requirements and the visibility conditions. For photopic conditions, the J2 visual acuity level was reached at 1 D of defocus for the 4 mm pupil diameter case, while for the 1.5 mm-diameter pupil, the J2 level was reached at 2.5 D. Binocular summation, defined as the ratio of binocular and the best monocular visual acuity, occurred only for distance targets. For near vision, binocular visual acuity closely followed the values of monocular visual acuity for the eye with the smaller aperture. In this case no binocular summation was observed in any of the subjects.

Conclusions: : The small-aperture effect to increase depth of focus in the human eye was successfully implemented and reproduced in a binocular adaptive optics visual simulator. Although certain limitations exist, the small-aperture approach provided a simple but attractive solution to effectively increase depth of focus in the human eye.

Keywords: binocular vision/stereopsis • presbyopia • aberrations 
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×