March 2012
Volume 53, Issue 14
Free
ARVO Annual Meeting Abstract  |   March 2012
A Pre-clinical Model For Chronic Electrical Stimulation Of The Retina Via Suprachoroidal Electrodes
Author Affiliations & Notes
  • David A. Nayagam
    Bionics Institute, East Melbourne, Australia
    Department of Pathology, University of Melbourne, Melbourne, Australia
  • Penelope J. Allen
    Centre for Eye Research Australia, Melbourne, Australia
    Royal Victorian Eye and Ear Hospital, Melbourne, Australia
  • Mohit N. Shivdasani
    Bionics Institute, East Melbourne, Australia
  • James B. Fallon
    Bionics Institute, East Melbourne, Australia
  • Chi D. Luu
    Centre for Eye Research Australia, Melbourne, Australia
  • Lauren N. Ayton
    Centre for Eye Research Australia, Melbourne, Australia
  • Melanie A. Gault
    Bionics Institute, East Melbourne, Australia
    Vanderbilt University, Nashville, Tennessee
  • Richard A. Williams
    Department of Pathology, University of Melbourne, Melbourne, Australia
    Anatomical Pathology, St Vincent's Hospital, Melbourne, Australia
  • Robert K. Shepherd
    Bionics Institute, East Melbourne, Australia
  • Chris E. Williams
    Bionics Institute, East Melbourne, Australia
    Department of Pathology, University of Melbourne, Melbourne, Australia
  • Footnotes
    Commercial Relationships  David A. Nayagam, None; Penelope J. Allen, None; Mohit N. Shivdasani, None; James B. Fallon, None; Chi D. Luu, None; Lauren N. Ayton, None; Melanie A. Gault, None; Richard A. Williams, None; Robert K. Shepherd, None; Chris E. Williams, None
  • Footnotes
    Support  Australian Research Council’s Bionic Vision Australia Initiative and Victorian Government through Operational Infrastructure Support Program
Investigative Ophthalmology & Visual Science March 2012, Vol.53, 5540. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      David A. Nayagam, Penelope J. Allen, Mohit N. Shivdasani, James B. Fallon, Chi D. Luu, Lauren N. Ayton, Melanie A. Gault, Richard A. Williams, Robert K. Shepherd, Chris E. Williams; A Pre-clinical Model For Chronic Electrical Stimulation Of The Retina Via Suprachoroidal Electrodes. Invest. Ophthalmol. Vis. Sci. 2012;53(14):5540.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: : To develop a model for assessing the safety and efficacy of chronically stimulating the retina at perceptually relevant levels with a suprachoroidal electrode array.

Methods: : Normally sighted adult cats were implanted, suprachoroidally, with anatomically conformable, medical grade, one-piece electrode arrays using a clinically viable approach. The array contained 12 active platinum (Pt) disc electrodes (600µm diameter), 2 Pt return electrodes (2mm diameter) and an extraocular Pt ball electrode. Extradural recording electrodes were implanted over the contralateral visual cortex. The lead assembly was tunnelled to an exteriorised connector. Following recovery the cats were fitted with wearable multichannel stimulators delivering biphasic current pulses at rates up to 200Hz for 3 months. Monopolar and common ground electrode geometries were used for stimulation and threshold measurements. Maximum charge density for active electrodes was 86µC/cm2. Capacitive coupling and electrode shorting were used to ensure charge balance. Stimulus intensities were above physiological and perceptual thresholds but below aversive levels. Eye health was assessed using electroretinography, optical coherence tomography and fundus photography. Individual electrode impedances were monitored weekly. Cortical evoked potential thresholds were measured regularly during the study. Multi-unit responses were recorded using multichannel ‘Utah’ arrays to confirm thresholds and verify the origin of the responses was primary visual cortex. Pathohistological assessments were performed using the contralateral eyes as controls.

Results: : Implant surgeries including extraorbital lead exit routing, lead tunnelling and fixation of recording electrodes were successful, lasting ~5 hours. Post-surgical complications were minimal and clinical assessments revealed normal retinal structure. Electrodes and lead assemblies remained viable throughout the study period. Impedances were 15-25kΩ at 2-weeks post-implantation (3-6kΩ pre-implantation in saline). Cortical evoked potential thresholds ranged from 200-600µA for current pulses of 400µs per phase. Suprathreshold stimulation was possible for electrodes within comfort levels.

Conclusions: : An animal model for assessing the safety and efficacy of chronic electrical stimulation of the retina has been developed. A robust one-piece electrode array and helical lead assembly was shown to be a viable approach for chronic suprachoroidal stimulation. Results of this study, including surgical techniques, safe stimulation levels and changes in impedances over time, will inform development of clinical retinal prostheses.

Keywords: electrophysiology: non-clinical • retinitis • pathology: experimental 
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×