April 2011
Volume 52, Issue 14
Free
ARVO Annual Meeting Abstract  |   April 2011
The Effect Of Induced Intraocular Straylight (cataract Simulation) On Sensitivity Measures Of Standard Automated Perimetry, Pulsar Perimetry And Moorfields Motion Displacement Test
Author Affiliations & Notes
  • Justyna D. Oleszczuk
    Jules Gonin Eye Hosp, Lausanne, CH, Lausanne, Switzerland
  • Ciara Bergin
    Jules Gonin Eye Hosp, Lausanne, CH, Lausanne, Switzerland
  • Eamon Sharkawi
    Jules Gonin Eye Hosp, Lausanne, CH, Lausanne, Switzerland
  • Footnotes
    Commercial Relationships  Justyna D. Oleszczuk, None; Ciara Bergin, None; Eamon Sharkawi, None
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science April 2011, Vol.52, 5518. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Justyna D. Oleszczuk, Ciara Bergin, Eamon Sharkawi; The Effect Of Induced Intraocular Straylight (cataract Simulation) On Sensitivity Measures Of Standard Automated Perimetry, Pulsar Perimetry And Moorfields Motion Displacement Test. Invest. Ophthalmol. Vis. Sci. 2011;52(14):5518.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: : To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).

Methods: : Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).

Results: : The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.

Conclusions: : The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.