April 2009
Volume 50, Issue 13
Free
ARVO Annual Meeting Abstract  |   April 2009
Determination of Anterior Chamber Volume: Agreement Between Pentacam and the Wang Formula for Visante OCT
Author Affiliations & Notes
  • G. Labiris
    Ophthalmology, Democritus University of Thrace, Alexandroupolis, Greece
  • A. Katsanos
    Ophthalmology, Democritus University of Thrace, Alexandroupolis, Greece
    Ophthalmology, University Hospital of Larissa, Larissa, Greece
  • M. Fanariotis
    Ophthalmology, Democritus University of Thrace, Alexandroupolis, Greece
  • M. Gika
    Ophthalmology, Democritus University of Thrace, Alexandroupolis, Greece
  • A. Koutsoyianni
    Ophthalmology, Democritus University of Thrace, Alexandroupolis, Greece
  • S. Alvanos
    Ophthalmology, Democritus University of Thrace, Alexandroupolis, Greece
  • P. Topalidou
    Ophthalmology, Democritus University of Thrace, Alexandroupolis, Greece
  • D. Mikropoulos
    1st Department of Ophthalmology, Aristotle University of Thessaloniki, Thessaloniki, Greece
  • V. Kozobolis
    Ophthalmology, Democritus University of Thrace, Alexandroupolis, Greece
  • Footnotes
    Commercial Relationships  G. Labiris, None; A. Katsanos, None; M. Fanariotis, None; M. Gika, None; A. Koutsoyianni, None; S. Alvanos, None; P. Topalidou, None; D. Mikropoulos, None; V. Kozobolis, None.
  • Footnotes
    Support  None.
Investigative Ophthalmology & Visual Science April 2009, Vol.50, 3670. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      G. Labiris, A. Katsanos, M. Fanariotis, M. Gika, A. Koutsoyianni, S. Alvanos, P. Topalidou, D. Mikropoulos, V. Kozobolis; Determination of Anterior Chamber Volume: Agreement Between Pentacam and the Wang Formula for Visante OCT. Invest. Ophthalmol. Vis. Sci. 2009;50(13):3670.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: : To evaluate the level of agreement between anterior chamber volume (ACV) measurements obtained with Pentacam and measurements obtained with the Wang formula for Visante-OCT.

Methods: : Volunteers with no anterior segment disease were recruited. Visante ACV measurements were obtained by means of the methodology proposed by Wang N. et al in 2007. A Bland-Altman analysis was performed to assess agreement between measurements with Pentacam and Visante-OCT.

Results: : One randomly selected eye from 30 participants was analysed. Spherical equivalent ranged between -2.50 D and +1.50 D. Mean±SD age was 56.3 ± 17.4 years with a range from 25 to 79 years. Mean±SD Pentacam ACV was 171.07 ± 39.64 µl (Vmin=103 µl and Vmax= 236 µl), while mean±SD Visante ACV was 171.38 ± 42.38 µl (Vmin=96.37 µl and Vmax= 245.54 µl). The mean difference between measurements was -0.318 and the 95% limits of agreement were -11.09 and 11.09. The differences between measurements were within the 95% limits of agreement in all but one eye.

Conclusions: : High levels of agreement were found between anterior chamber volume measurements obtained with Pentacam and measurements obtained with Visante-OCT when the Wang formula was used.

Keywords: anterior chamber • topography • imaging methods (CT, FA, ICG, MRI, OCT, RTA, SLO, ultrasound) 
×
×