April 2009
Volume 50, Issue 13
Free
ARVO Annual Meeting Abstract  |   April 2009
Oraya’s IRayTM System for Delivery of Microcollimated Pars Plana External Beam Radiation to the Eye: Local Safety and Patient Tolerability
Author Affiliations & Notes
  • R. Velez-Montoya
    Retina Department, Asociacion para Evitar la Ceguera en Mexico, Mexico, Mexico
  • M. J. López-Miranda
    Retina Department, Asociacion para Evitar la Ceguera en Mexico, Mexico, Mexico
  • C. Cortes-Alcocer
    Retina Department, Asociacion para Evitar la Ceguera en Mexico, Mexico, Mexico
  • F. Hernández-Miranda
    Retina Department, Asociacion para Evitar la Ceguera en Mexico, Mexico, Mexico
  • D. Moshfeghi
    Department of Ophthalmology, Stanford University, School of Medicine, Stanford,, San Francisco, California
  • M. E. Shusterman
    Oraya Therapeutics, Inc., San Francisco, California
  • H. Quiroz-Mercado
    Ophthalmology, Denver Health Medical Center, School of Medicine. University of Colorado, Denver, Colorado
  • V. Morales-Cantón
    Retina Department, Asociacion para Evitar la Ceguera en Mexico, Mexico, Mexico
  • Footnotes
    Commercial Relationships  R. Velez-Montoya, None; M.J. López-Miranda, None; C. Cortes-Alcocer, None; F. Hernández-Miranda, None; D. Moshfeghi, None; M.E. Shusterman, Oraya Therapeutics, Inc., E; H. Quiroz-Mercado, None; V. Morales-Cantón, Oraya Therapeutics, Inc., R.
  • Footnotes
    Support  None.
Investigative Ophthalmology & Visual Science April 2009, Vol.50, 5007. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      R. Velez-Montoya, M. J. López-Miranda, C. Cortes-Alcocer, F. Hernández-Miranda, D. Moshfeghi, M. E. Shusterman, H. Quiroz-Mercado, V. Morales-Cantón; Oraya’s IRayTM System for Delivery of Microcollimated Pars Plana External Beam Radiation to the Eye: Local Safety and Patient Tolerability. Invest. Ophthalmol. Vis. Sci. 2009;50(13):5007.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: : Oraya’s IRay is an investigational office-based device, which delivers low energy X-rays to the macula for treatment of choroidal neovascularization due to age-related macular degeneration. It combines a robotically positioned 100 keV X-ray tube, eye alignment and tracking via the I-GuideTM scleral cup, treatment planning, and automated safety features. The beams are highly collimated, with a diameter of 3.5 mm on the sclera and 4 mm on the retina. Clinically, IRay delivers up to 22 Gy to the 90% isodose, using 3 sequential beams which pass through the sclera and overlap at the macula. The aim of this study was to describe the safety and patient tolerability of the radiotherapy procedure.

Methods: : We included 32 patients treated with the IRay system. Every patient had a complete ophthalmologic examination at baseline, 10 minutes, and one week after treatment. We intentionally searched for local adverse effects (AEs) during examination and by interviewing the patients. We recorded type, duration and treatments if needed for every AE.

Results: : All patients presented with mild superficial punctate keratitis (SPK) secondary to the I-Guide. This was noted at ophthalmic examination but no symptoms were reported by any patient. All cases lasted less than a week and needed no treatment. There were no other local AEs or reports of discomfort.

Conclusions: : Treatment with Oraya’s IRay system is safe and well tolerated in the short term. The only AE reported (SPK) is a common reaction with the use of all devices which include a contact lens.

Keywords: age-related macular degeneration • radiation therapy • choroid: neovascularization 
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×