April 2009
Volume 50, Issue 13
Free
ARVO Annual Meeting Abstract  |   April 2009
Relations Between Ocular Astigmatism and Corneal Astigmatism
Author Affiliations & Notes
  • E. Basli
    Service 5, 15-20 National Hospital of Ophthalmology, Paris, France
  • O. Touzeau
    Service 5, 15-20 National Hospital of Ophthalmology, Paris, France
  • E. Costantini
    Service 5, 15-20 National Hospital of Ophthalmology, Paris, France
  • T. Gaujoux
    Service 5, 15-20 National Hospital of Ophthalmology, Paris, France
  • C. Allouch
    Service 5, 15-20 National Hospital of Ophthalmology, Paris, France
  • L. Laroche
    Service 5, 15-20 National Hospital of Ophthalmology, Paris, France
  • V. M. Borderie
    Service 5, 15-20 National Hospital of Ophthalmology, Paris, France
  • Footnotes
    Commercial Relationships  E. Basli, None; O. Touzeau, None; E. Costantini, None; T. Gaujoux, None; C. Allouch, None; L. Laroche, None; V.M. Borderie, None.
  • Footnotes
    Support  None.
Investigative Ophthalmology & Visual Science April 2009, Vol.50, 5103. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      E. Basli, O. Touzeau, E. Costantini, T. Gaujoux, C. Allouch, L. Laroche, V. M. Borderie; Relations Between Ocular Astigmatism and Corneal Astigmatism. Invest. Ophthalmol. Vis. Sci. 2009;50(13):5103.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: : To investigate the relations between ocular (refractive) astigmatism and corneal (anterior and posterior) astigmatism in a normal population.

Methods: : We prospectively recorded ocular astigmatism (manifest refraction and autorefractometry data) and corneal astigmatism of 500 healthy eyes (including ametropia) of 250 patients by using Orbscan topography. Polar values (cylinder, axis) of regular astigmatism were transformed into rectangular coordinates (x,y) which respectively represent WTR/ATR component (0°/90° Jackson Crossed-Cylinder) and oblique component (45°/135°JCC). Total (anterior + posterior) corneal astigmatism and internal astigmatism were calculed by vectorial method.

Results: : Anterior corneal cylinder showed higher correlation with subjective cylinder (r: 0.84 to 0.89 p<0.001) than total cylinder (r=0.83 p<0.001) or posterior cylinder (r=0.64 p<0.001). Posterior corneal astigmatism data did not improve the prediction of subjective axis or cylinder. The relative proportion of both components of astigmatism (WTR/ATR and oblique) was not correlated with cylinder. Axis of subjective astigmatism was unaffected by corneal or ocular cylinder (p>0.05). The relative proportion of the anterior corneal astigmatism in the subjective astigmatism was correlated with the subjective cylinder (r=0.54 p<0.001; 83% when cylinder ≥3.00D; 52% when cylinder ≤0.50D). Autorefractometer was the best device to predict subjective cylinder in particularly when cylinder value is weak (r=0.90 p<0.001). The difference (in absolute value) between subjective and corneal axis decreased when the cylinder increased (r=-0.42 p<0.001).

Conclusions: : Anterior corneal astigmatism plays major role in ocular astigmatism especially when the magnitude of the last is important.

Keywords: cornea: clinical science • astigmatism • refraction 
×
×