April 2009
Volume 50, Issue 13
Free
ARVO Annual Meeting Abstract  |   April 2009
Retinal Drusen Detection Using the Nidek F-10 SLO in Retro-Mode
Author Affiliations & Notes
  • J. M. Gibson
    Vision Sciences, Aston University, Birmingham, Birmingham, United Kingdom
  • J. Acton
    Vision Sciences, Aston University, Birmingham, Birmingham, United Kingdom
  • E. Berrow
    Ophthalmology, Heart of England NHS Foundation Trust, Solihull, United Kingdom
  • P. Galsworthy
    Ophthalmology, Heart of England NHS Foundation Trust, Birmingham, United Kingdom
  • H. King
    Ophthalmology, Heart of England NHS Foundation Trust, Birmingham, United Kingdom
  • L. Quant
    Ophthalmology, Heart of England NHS Foundation Trust, Birmingham, United Kingdom
  • K. Whitehouse
    Ophthalmology, Heart of England NHS Foundation Trust, Birmingham, United Kingdom
  • Footnotes
    Commercial Relationships  J.M. Gibson, None; J. Acton, None; E. Berrow, None; P. Galsworthy, None; H. King, None; L. Quant, None; K. Whitehouse, None.
  • Footnotes
    Support  None.
Investigative Ophthalmology & Visual Science April 2009, Vol.50, 5262. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      J. M. Gibson, J. Acton, E. Berrow, P. Galsworthy, H. King, L. Quant, K. Whitehouse; Retinal Drusen Detection Using the Nidek F-10 SLO in Retro-Mode. Invest. Ophthalmol. Vis. Sci. 2009;50(13):5262.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: : We conducted a small study to assess the novel, retro - mode imaging technique of the NIDEK F-10 scanning laser ophthalmoscope, for detecting and quantifying retinal drusen.

Methods: : Fundus photographs of 4 eyes of 2 patients taken in retro-mode on the Nidek F-10 SLO were graded independently by 6,experienced, masked fundus graders for the presence of retinal drusen , and compared to stereo colour fundus photographs taken with a Topcon TRC-50DX camera.

Results: : The mean number of retinal drusen detected in retro mode was 142.96+/- 60.8, range 63-265, and on colour fundus photography mean of 66.6+/-32.6, range 26-177. All observers independently detected approximately twice as many drusen on retro-mode than colour fundus photography (p<0.0001, Student’s paired t-test) . The statistical significance of interobserver variation in drusen detection was p=0.07 on colour fundus photography , and p=0.02 on retro mode ( ANOVA) .

Conclusions: : The retro-mode of the F-10 camera uses infrared laser and an aperture with a modified central stop, with the aperture deviated laterally from the confocal light path. This forms a pseudo -3D image which is a new means of detecting abnomalites in the deeper retinal layers. Retro-mode imaging of retinal drusen using the F-10 Nidek SLO is a highly sensitive technique for detecting and quantifying retinal drusen , and detected twice as many drusen than colour fundus photography. This small pilot study suggests that this novel type of imaging may have a role in the future detection and analysis of retinal drusen, a field that is likely to become increasingly important in future AMD prevention studies.

Keywords: drusen • imaging methods (CT, FA, ICG, MRI, OCT, RTA, SLO, ultrasound) 
×
×