Examining the Agreement of Structural Loss Measured With Heidelberg Retinal Tomograhy and Functional Loss With Standard Automated Perimetry (SAP; Octopus), Pulsar Perimetry (PP), and Moorfields Motion Displacement Test (MDT) Perimetry
Author Affiliations & Notes
  • C. C. Schnyder
    Jules Gonin Eye Hospital, Lausanne, Switzerland
  • J. Oleszczuk
    Jules Gonin Eye Hospital, Lausanne, Switzerland
  • C. Bergin
    Department of Optometry and Visual Sciences, City University, London, United Kingdom
  • W. Ferrini
    Jules Gonin Eye Hospital, Lausanne, Switzerland
  • D. Rivier
    Jules Gonin Eye Hospital, Lausanne, Switzerland
  • G. M. Verdon-Roe
    NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
  • E. Sharkawi
    Jules Gonin Eye Hospital, Lausanne, Switzerland
  • Footnotes
    Commercial Relationships  C.C. Schnyder, None; J. Oleszczuk, None; C. Bergin, Moorfields MDT, P; W. Ferrini, None; D. Rivier, None; G.M. Verdon-Roe, Moorfields MDT, P; E. Sharkawi, None.
  • Footnotes
    Support  None.
Investigative Ophthalmology & Visual Science April 2010, Vol.51, 4902. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      C. C. Schnyder, J. Oleszczuk, C. Bergin, W. Ferrini, D. Rivier, G. M. Verdon-Roe, E. Sharkawi; Examining the Agreement of Structural Loss Measured With Heidelberg Retinal Tomograhy and Functional Loss With Standard Automated Perimetry (SAP; Octopus), Pulsar Perimetry (PP), and Moorfields Motion Displacement Test (MDT) Perimetry. Invest. Ophthalmol. Vis. Sci. 2010;51(13):4902.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: : To examine the relationship of functional measurements with structural measures.

Methods: : 146 eyes of 83 test subjects underwent Heidelberg Retinal Tomography (HRTIII) (disc area<2.43, mphsd<40), and perimetry testing with Octopus (SAP; Dynamic), Pulsar (PP; TOP) and Moorfields MDT (ESTA). Glaucoma was defined as progressive structural or functional loss (20 eyes). Perimetry test points were grouped into 6 sectors based on the estimated optic nerve head angle into which the associated nerve fiber bundle enters (Garway-Heath map). Perimetry summary measures (PSM) (MD SAP/ MD PP/ PTD MDT) were calculated from the average total deviation of each measured threshold from the normal for each sector. We calculated the 95% significance level of the sectorial PSM from the respective normative data. We calculated the percentage agreement with group1 (G1), healthy on HRT and within normal perimetric limits, and group 2 (G2), abnormal on HRT and outside normal perimetric limits. We also examined the relationship of PSM and rim area (RA) in those sectors classified as abnormal by MRA (Moorfields Regression Analysis) of HRT.

Results: : The mean age was 65 (range= [37, 89]). The global sensitivity versus specificity of each instrument in detecting glaucomatous eyes was: MDT 80% vs. 88%, SAP 80% vs. 80%, PP 70% vs. 89% and HRT 80% vs. 79%. Highest percentage agreement of HRT (respectively G1, G2, sector) with PSM were MDT (89%, 57%, nasal superior), SAP (83%, 74%, temporal superior), PP (74%, 63%, nasal superior). Globally percentage agreement (respectively G1, G2) was MDT (92%, 28%), SAP (87%, 40%) and PP (77%, 49%). Linear regression showed there was no significant trend globally associating RA and PSM. However, sectorally the supero-nasal sector had a statistically significant (p<0.001) trend with each instrument, the associated r2 coefficients are (MDT 0.38 SAP 0.56 and PP 0.39).

Conclusions: : There were no significant differences in global sensitivity or specificity between instruments. Structure-function relationships varied significantly between instruments and were consistently strongest supero-nasally. Further studies are required to investigate these relationships in detail.

Keywords: imaging methods (CT, FA, ICG, MRI, OCT, RTA, SLO, ultrasound) • visual fields • optic disc 
×
×