April 2010
Volume 51, Issue 13
Free
ARVO Annual Meeting Abstract  |   April 2010
A Semi-Automatic Linear Regression-Based Method to Measure the Ciliary Body-Sclera Angle in Ultrasound Biomicroscopy Images
Author Affiliations & Notes
  • I. H. Chan
    Ophthalmology, New York Eye and Ear Infirmary, New York, New York
  • S. K. Dorairaj
    Glaucoma, Einhorn Rsch Center, NYEE, New York, New York
  • T. S. Prata
    Ophthalmology,
    New York Eye & Ear Infirmary, New York, New York
  • J. Panarelli
    Ophthalmology, New York Eye and Ear Infirmary, New York, New York
  • P. A. Sidoti
    Department of Ophthalmology,
    New York Eye & Ear Infirmary, New York, New York
  • R. Ritch
    Ophthalmology,
    New York Eye & Ear Infirmary, New York, New York
  • Footnotes
    Commercial Relationships  I.H. Chan, None; S.K. Dorairaj, None; T.S. Prata, None; J. Panarelli, None; P.A. Sidoti, None; R. Ritch, None.
  • Footnotes
    Support  None.
Investigative Ophthalmology & Visual Science April 2010, Vol.51, 5533. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      I. H. Chan, S. K. Dorairaj, T. S. Prata, J. Panarelli, P. A. Sidoti, R. Ritch; A Semi-Automatic Linear Regression-Based Method to Measure the Ciliary Body-Sclera Angle in Ultrasound Biomicroscopy Images. Invest. Ophthalmol. Vis. Sci. 2010;51(13):5533.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract
 
Purpose:
 

To measure the ciliary body-sclera angle (CBSA) in UBM.

 
Methods:
 

Morphological structure element is used for image segmentation of angle structures. The inner corneal border and anterior border of the ciliary body are linearly fitted. The angle formed by the 2 intersecting lines is defined as CBSA. 3 observers measure the CBSA in 20 UBM images each 3 times. Intra-class correlation coefficient (ICC) is used to measure intra- and inter-observer variability.

 
Results:
 

CBSA Mean (STD) = 56.27 (16.04) deg. ICC(agreement) = 0.9984. ICC(consistency) = 0.9986.

 
Conclusions:
 

This semi-automatic linear-regression based measurement of CBSA in UBM achieves excellent inter- and intra-observer agreement. This method can consistently evaluate the ciliary body morphology.  

 
Keywords: ciliary body • ciliary muscle • ciliary processes 
×
×