May 2008
Volume 49, Issue 13
Free
ARVO Annual Meeting Abstract  |   May 2008
Long-Term Reliability of Polyimide Electrode Array in Rabbit Retina
Author Affiliations & Notes
  • E. Kim
    School of Electrical Engineering and Computer Science, Seoul National University, Seoul, Republic of Korea
    Nano Artificial Vision Research Center, Nano Bioelectronics & System Research Center, Seoul, Republic of Korea
  • S. Lee
    School of Electrical Engineering and Computer Science, Seoul National University, Seoul, Republic of Korea
    Nano Artificial Vision Research Center, Nano Bioelectronics & System Research Center, Seoul, Republic of Korea
  • J.-M. Seo
    School of Electrical Engineering and Computer Science, Seoul National University, Seoul, Republic of Korea
    Nano Artificial Vision Research Center, Nano Bioelectronics & System Research Center, Seoul, Republic of Korea
  • H. Chung
    Nano Artificial Vision Research Center, Nano Bioelectronics & System Research Center, Seoul, Republic of Korea
    Ophthalmology, Seoul National University School of Medicine, Seoul, Republic of Korea
  • S. Kim
    School of Electrical Engineering and Computer Science, Seoul National University, Seoul, Republic of Korea
    Nano Artificial Vision Research Center, Nano Bioelectronics & System Research Center, Seoul, Republic of Korea
  • Footnotes
    Commercial Relationships  E. Kim, None; S. Lee, None; J. Seo, None; H. Chung, None; S. Kim, None.
  • Footnotes
    Support  Korea Health 21 R&D Project MOHW A050251, NBS-ERC supported by KOSEF
Investigative Ophthalmology & Visual Science May 2008, Vol.49, 1773. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      E. Kim, S. Lee, J.-M. Seo, H. Chung, S. Kim; Long-Term Reliability of Polyimide Electrode Array in Rabbit Retina. Invest. Ophthalmol. Vis. Sci. 2008;49(13):1773.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: : Long-term reliability of polyimide-based gold electrode array for retinal prosthesis was evaluated in the rabbit eye for 2 years, and as a result, a novel fabrication process including oxygen plasma treatment and geometrical grid between layers was proposed to improve the reliability of the electrode array.

Methods: : Polyimide-based gold electrode array was fabricated by previously proposed method (Chung, 2002), and was subretinally implanted in the rabbit eye. After two years of implantation, electrode array was harvested and examined. To investigate the mechanism of changes in vivo, it was mimicked by in vitro temperature elevation in phosphate buffered saline (PBS: pH7.4). Pressure induction test (blister test) was introduced to measure the strength of adhesion between layers and was done periodically during in vitro test. New design ideas to lengthen lifetime were proposed. Several novel steps were introduced between the fabrication processes to enhance the interlayer bonding strength. Oxygen plasma treatment for reactive ion etching was done along the margin of the electrode sites and pads for tight sealing between the layers. Grid design was introduced for increasing contact area between lower and upper layers. Several groups with different size of grid were designed and tested.

Results: : There was minute delamination between the layers along the edge of the electrode site opening without melting or corrosion of the polyimide or gold material. Delamination mechanism was successfully reproduced by in vitro PBS soak test with temperature elevation and blister test helped to analyze the change of adhesion strength according to the time course. Newly proposed fabrication steps, oxygen plasma treatment and geometrical grid, was shown to enhance adhesion strength more than 20(psi) compared to previous art of design.

Conclusions: : Long-term implantation of polyimide electrode array fabricated by previously proposed method was proved to have some shortcoming in vivo, and successfully reproduced by in vitro acceleration setup. Proposed oxygen plasma treatment and geometrical grid design was tested and could be successfully used for enhancing long-term stability of the electrode array for artificial retina.