May 2007
Volume 48, Issue 13
Free
ARVO Annual Meeting Abstract  |   May 2007
Dual-Metal-Layer Parylene-Based Flexible Electrode Arrays for Intraocular Retinal Prostheses
Author Affiliations & Notes
  • D. C. Rodger
    Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California
    Doheny Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, California
  • W. Li
    Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California
  • H. Ameri
    Doheny Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, California
  • S. Saati
    Doheny Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, California
  • P. Menon
    Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California
  • E. Meng
    Doheny Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, California
  • J. D. Weiland
    Doheny Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, California
  • M. S. Humayun
    Doheny Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, California
  • Y.-C. Tai
    Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California
  • Footnotes
    Commercial Relationships D.C. Rodger, California Institute of Technology, P; W. Li, California Institute of Technology, P; H. Ameri, University of Southern California, P; S. Saati, None; P. Menon, None; E. Meng, None; J.D. Weiland, University of Southern California, P; M.S. Humayun, University of Southern California, P; Y. Tai, California Institute of Technology, P.
  • Footnotes
    Support NSF Grant EEC-0310723
Investigative Ophthalmology & Visual Science May 2007, Vol.48, 657. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      D. C. Rodger, W. Li, H. Ameri, S. Saati, P. Menon, E. Meng, J. D. Weiland, M. S. Humayun, Y.-C. Tai; Dual-Metal-Layer Parylene-Based Flexible Electrode Arrays for Intraocular Retinal Prostheses. Invest. Ophthalmol. Vis. Sci. 2007;48(13):657.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose:: To design, fabricate, and perform electrical and biostability tests of a parylene-based dual-metal-layer epiretinal 1024 electrode array with a biomimetic layout that closely matches the density of macular ganglion cells.

Methods:: A layer of parylene C was deposited on sacrificial photoresist on silicon, followed by the deposition and patterning of a layer of titanium/platinum traces with 16 µm pitch. A thin insulating layer of parylene was deposited and vias patterned using O2 plasma to enable electrical contact to a subsequently deposited second layer of electrodes and traces. A third layer of parylene was deposited to achieve topside insulation, the electrodes were exposed, the 5 mm by 6 mm array and cable geometry etched, and the implants were released in acetone. 60 of 1024 biomimetically arranged 75 µm-diameter electrodes were connected to two contacts each to test electrical conductivity over the traces and vias. The implants were annealed to optimize parylene-parylene adhesion and curved using a custom mold to approximate the curvature of the canine retina, sterilized, and implanted in the OD of two canines through a pars plana incision and were tacked to the retina. Follow up studies after three and two months respectively including fluorescein angiography (FA) and optical coherence tomography (OCT) are underway to assess the chronic biostability of the implant and the retina.

Results:: Electrical testing of the two traces connected to each electrode demonstrated a typical impedance of ~5 kΩ, which includes two 8 µm-wide traces of 20 mm-length as well as two via step junctions. Each via has an impedance of less than 12.5 Ω. The arrays retained the desired retinal curvature after sterilization. Implantation was successful, with one animal later developing a lens opacity due to nicking during implantation. OCT showed that the array was within 50 µm of the retina in the center and slightly lifted at the edges. FA shows minimal to no leakage around the perimeter of each array and underneath the array retinal vessels filled normally. Some hyperpigmentation was noted at the tack site.

Conclusions:: High density electrode arrays with a biomimetic design have been fabricated according to a novel dual-metal-layer process, with electrical conductivity between the two layers being verified. Prototype implants have been chronically implanted epiretinally and have shown nominal biomechanical behavior during follow up.

Keywords: retina • age-related macular degeneration • vitreoretinal surgery 
×
×

This PDF is available to Subscribers Only