May 2007
Volume 48, Issue 13
Free
ARVO Annual Meeting Abstract  |   May 2007
Effect of Aberration Correction on Visual Acuity in the Periphery
Author Affiliations & Notes
  • L. Lundstrom
    Biomedical and X-Ray Physics, Royal Institute of Technology, Stockholm, Sweden
  • N. Gorceix
    Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
  • S. Manzanera
    Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
  • P. M. Prieto
    Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
  • D. B. Ayala
    Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
  • Jö. Gustafsson
    School of Optometry, Kalmar University, Kalmar, Sweden
  • P. Unsbo
    Biomedical and X-Ray Physics, Royal Institute of Technology, Stockholm, Sweden
  • P. Artal
    Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
  • Footnotes
    Commercial Relationships L. Lundstrom, None; N. Gorceix, None; S. Manzanera, None; P.M. Prieto, None; D.B. Ayala, None; J. Gustafsson, None; P. Unsbo, None; P. Artal, None.
  • Footnotes
    Support MEC_FIS2004-2153 (Spain)
Investigative Ophthalmology & Visual Science May 2007, Vol.48, 4003. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      L. Lundstrom, N. Gorceix, S. Manzanera, P. M. Prieto, D. B. Ayala, Jö. Gustafsson, P. Unsbo, P. Artal; Effect of Aberration Correction on Visual Acuity in the Periphery. Invest. Ophthalmol. Vis. Sci. 2007;48(13):4003.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose:: The limit to resolution acuity in the periphery can be either optical or retinal. Although retinal sampling poses an eventual limit, optical aberrations may set a more stringent limit. In this study, we investigate the impact of different optical corrections on acuity in the periphery.

Methods:: We used the adaptive optics visual simulator at the University of Murcia to measure and modify the off-axis aberrations of the right eye of six normal subjects at 20° of eccentricity (left horizontal meridian). The system consists of a Hartmann-Shack sensor, a deformable mirror (Xinetics, 97 actuators), and a channel for visual testing. Four different optical corrections were tested: foveal correction; eccentric defocus correction; eccentric sphero-cylindrical correction; and full correction of eccentric low and high order monochromatic aberrations. High-contrast visual acuity was measured in green light using a forced choice procedure with Landolt Cs, viewed via the deformable mirror through a 4.8-mm artificial pupil.

Results:: Defocus and horizontal-vertical astigmatism, C(2,2), were the terms mainly affected by eccentricity. At 20° in the periphery, the changes in defocus were subject-dependent, while C(2,2) was consistently modified toward positive values. Each correction condition was successfully implemented on each subject, and the final average RMS values, including defocus, were: 1.01 ± 0.26 µm; 0.83 ± 0.30 µm; 0.41 ± 0.06 µm; and 0.05 ± 0.02 µm, respectively. Although there was a general mild tendency of improvement in visual acuity with the successive corrections, the differences were in general small and not significant.

Conclusions:: Correcting optical aberrations at 20° of eccentricity in the periphery produces only slight improvements in visual acuity. This suggests that for our experimental conditions and subjects, the resolution-limiting factor is retinal sampling instead of optical errors. However, it should be noted that our experiment does not rule out the possibility of improvements in detection tasks or low contrast resolution acuity in the periphery.

Keywords: visual acuity • refraction • optical properties 
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×