May 2007
Volume 48, Issue 13
Free
ARVO Annual Meeting Abstract  |   May 2007
Influence of Wear on Bacterial Adhesion and Disinfection to Silicone Hydrogel Contact Lenses
Author Affiliations & Notes
  • Lí. Santos
    University of Minho, Braga, Portugal
    Centre of Biological Engineering,
  • D. Rodrigues
    University of Minho, Braga, Portugal
    Centre of Biological Engineering,
  • M. Lira
    University of Minho, Braga, Portugal
    Centre of Physics,
  • M. E. C. D. Real Oliveira
    University of Minho, Braga, Portugal
    Centre of Physics,
  • R. Oliveira
    University of Minho, Braga, Portugal
    Centre of Biological Engineering,
  • J. Azeredo
    University of Minho, Braga, Portugal
    Centre of Biological Engineering,
  • Footnotes
    Commercial Relationships L. Santos, None; D. Rodrigues, None; M. Lira, None; M.E.C.D. Real Oliveira, None; R. Oliveira, None; J. Azeredo, None.
  • Footnotes
    Support None.
Investigative Ophthalmology & Visual Science May 2007, Vol.48, 5378. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Lí. Santos, D. Rodrigues, M. Lira, M. E. C. D. Real Oliveira, R. Oliveira, J. Azeredo; Influence of Wear on Bacterial Adhesion and Disinfection to Silicone Hydrogel Contact Lenses. Invest. Ophthalmol. Vis. Sci. 2007;48(13):5378.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose:: The aim of this work was to determine the effect of wear in microbial cell adhesion to silicone-hydrogel contact lenses (CL) and in the performance of a multipurpose solution (MPS). Hydrophobicity was accessed to unworn and worn CL in order to evaluate the existence of surface changes induced by wear.

Methods:: Worn and unworn CL were colonised by a clinical strain of Staphylococcus epidermidis through a dynamic adhesion assay performed in a parallel plate flow chamber. The same device was used to study the efficacy of the MPS (ReNu MultiPlus, Bausch & Lomb, Rochester, NY) in detaching adhered cells and the percentage of remaining dead cells was determined by propidium iodide staining. Lens surface hydrophobicity was determined through contact angle measurements using the advancing type technique in air. In this study were tested four silicone hydrogel CL (Galyfilcon A, Balafilcon A, Lotrafilcon A, Lotrafilcon B) and one conventional hydrogel (Etafilcon A).

Results:: Worn silicone hydrogel CL were equally or less prone for microbial adhesion than unworn lenses, whereas worn conventional hydrogel CL exhibited a greater extent of microbial adhesion. This fact was related with changes in surface hydrophobicity of worn CL, probably due to the adsorption of tear film molecules. The MPS detachment capability from both unworn and worn CL was similar; however the percentage of dead cells after MPS's application was superior to worn CL.

Conclusions:: Lens surface hydrophobicity is highly modified during wear and this fact influences microbial adhesion. The detachment capability of the MPS was similar to unworn and worn CL. However, worn lenses exhibited a superior amount of dead cells.

Keywords: Staphylococcus • contact lens • microscopy: light/fluorescence/immunohistochemistry 
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×