May 2005
Volume 46, Issue 13
Free
ARVO Annual Meeting Abstract  |   May 2005
Correlating Structure With Function in End–stage Glaucoma
Author Affiliations & Notes
  • E.Z. Blumenthal
    Dept of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel
  • A. Horani
    Dept of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel
  • R. Sasikumar
    L.V. Prasad Eye Institute, Hyderabad, India
  • G.C. Sekhar
    L.V. Prasad Eye Institute, Hyderabad, India
  • A. Udaykumar
    L.V. Prasad Eye Institute, Hyderabad, India
  • R. Thomas
    L.V. Prasad Eye Institute, Hyderabad, India
  • Footnotes
    Commercial Relationships  E.Z. Blumenthal, Laser Diagnostic Technologies F; A. Horani, None; R. Sasikumar, None; G.C. Sekhar, None; A. Udaykumar, None; R. Thomas, None.
  • Footnotes
    Support  None.
Investigative Ophthalmology & Visual Science May 2005, Vol.46, 2536. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      E.Z. Blumenthal, A. Horani, R. Sasikumar, G.C. Sekhar, A. Udaykumar, R. Thomas; Correlating Structure With Function in End–stage Glaucoma . Invest. Ophthalmol. Vis. Sci. 2005;46(13):2536.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Abstract: : Purpose: To correlate structure and function in end–stage glaucoma eyes, using scanning laser polarimetry (SLP) as a measure of structure, and standard achromatic perimetry (SAP) as a measure of the functional status of the eye. Methods: Fifty–six eyes of 48 glaucoma patients presenting with end–stage glaucoma, as defined by both a glaucomatous optic disc with a vertical cup–to–disk (C/D) ratio of >0.9, and a SAP visual field (VF) criteria (mean deviation (MD) worse than –20dB) underwent SLP imaging using the GDX VCC unit. Patients were recruited at two tertiary referral centers: Hadassah Hospital, Jerusalem, and L.V. Prasad Eye Institute, Hyderabad. Results: The VF MD was: –26.75 ± 3.50. The remaining RNFL layer, as measured using SLP, in this group of eyes was: TSNIT Average: 29.76 ± 5.81; Superior Average: 30.76 ± 6.25; Inferior Average: 31.14 ± 7.20. Poor structure–function correlation was found when analyzing separately the superior and the inferior hemifields (r2=0.003, r2=0.04, respectively). Conclusions: In eyes with end–stage glaucoma little remaining RNFL is found with scanning laser polarimetry, however, these values rarely drop below 10–20 microns. A flattening of the GDx TSNIT pattern is evident, and the correlation between structure and function is mostly lost.

Keywords: imaging methods (CT, FA, ICG, MRI, OCT, RTA, SLO, ultrasound) • visual fields • wound healing 
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×