May 2005
Volume 46, Issue 13
Free
ARVO Annual Meeting Abstract  |   May 2005
Axial Length and IOP Changes With Application of the IntraLase and Moria M2 Suction Rings
Author Affiliations & Notes
  • W.W. Culbertson
    Ophthalmology, Bascom Palmer Eye Institute, Miami, FL
  • F. Marangon
    Ophthalmology, Bascom Palmer Eye Institute, Miami, FL
  • S.H. Yoo
    Ophthalmology, Bascom Palmer Eye Institute, Miami, FL
  • C.A. Acosta
    Ophthalmology, Bascom Palmer Eye Institute, Miami, FL
    Hospital Oftalmológico Dr. P.Lagleyze, Buenos Aires, Argentina
  • I. Nose
    Ophthalmology, Bascom Palmer Eye Institute, Miami, FL
  • P. Superfine
    Ophthalmology, Bascom Palmer Eye Institute, Miami, FL
  • J. Parel
    Ophthalmology, Bascom Palmer Eye Institute, Miami, FL
    CHU Sart–Tilman, Univ. of Liege, Liege, Belgium
  • Footnotes
    Commercial Relationships  W.W. Culbertson, Intralase R; F. Marangon, None; S.H. Yoo, Intralase R; C.A. Acosta, None; I. Nose, None; P. Superfine, None; J. Parel, None.
  • Footnotes
    Support  NIH center grant P30–EY014801; Research to Prevent Blindness; Henri and Flore Lesieur Foundation
Investigative Ophthalmology & Visual Science May 2005, Vol.46, 4338. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      W.W. Culbertson, F. Marangon, S.H. Yoo, C.A. Acosta, I. Nose, P. Superfine, J. Parel; Axial Length and IOP Changes With Application of the IntraLase and Moria M2 Suction Rings . Invest. Ophthalmol. Vis. Sci. 2005;46(13):4338.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Abstract: : Purpose: To determine how the axial length and the intraocular pressure changes when the IntraLase suction ring interface and the Moria M2 suction ring are placed on the human eye. Methods: Ten fresh human cadaver eyes (five pairs) and six eyes (three pairs) of living volunteers were studied. Intraocular pressures and axial lengths were obtained both prior to and during application of an IntraLase suction ring to one of a pair of the eyes. Similar measurements were obtained with application of a Moria M2 suction ring. Results: Intraocular pressures increased with both suction rings to between 71 to 84 mmHg during application of suction in both living and cadaver eyes. Axial lengths either remained unchanged or shortened during suction application in both IntraLase and Moria M2 cadaver or living human eyes. The average decrease in axial lengths was 0.47mm for IntraLase cadaver eyes and 82mm for Moria cadaver eyes. In three pairs of living volunteer eyes the axial length shortened on the average of 0.19mm for IntraLase eyes and 0.12mm for Moria M2 eyes. Conclusions: The intraocular pressure is raised significantly when either the IntraLase or the Moria M2 suction ring is applied to the human eye. Contrary to recent reports of elongation of axial length with the Moria M2 suction ring (Flaxel et al, Ophth 111:24–27;2004), we found that the axial length decreases (instead of increases) when either type of suction ring is applied to living or cadaver human eyes.

Keywords: anterior chamber • imaging methods (CT, FA, ICG, MRI, OCT, RTA, SLO, ultrasound) • refractive surgery: LASIK 
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×