May 2004
Volume 45, Issue 13
Free
ARVO Annual Meeting Abstract  |   May 2004
Quantification Of Photoreceptor Layer Thickness Using Ultrahigh Resolution Optical Coherence Tomography
Author Affiliations & Notes
  • B. Hermann
    Department of Medical Physics, University of Vienna, Vienna, Austria
  • A. Unterhuber
    Department of Medical Physics, University of Vienna, Vienna, Austria
  • M. Wirtitsch
    Department of Ophthalmology, General Hospital of Vienna, Vienna, Austria
  • M. Stur
    Department of Ophthalmology, General Hospital of Vienna, Vienna, Austria
  • E. Ergun
    Department of Ophthalmology, General Hospital of Vienna, Vienna, Austria
  • C. Scholda
    Department of Ophthalmology, General Hospital of Vienna, Vienna, Austria
  • T. Ko
    Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA
  • J.S. Schuman
    UPMC Eye Center, Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, PA
  • J.G. Fujimoto
    Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA
  • W. Drexler
    Department of Medical Physics, University of Vienna, Vienna, Austria
  • Footnotes
    Commercial Relationships  B. Hermann, None; A. Unterhuber, None; M. Wirtitsch, None; M. Stur, None; E. Ergun, None; C. Scholda, None; T. Ko, None; J.S. Schuman, None; J.G. Fujimoto, CARL ZEISS Meditec C; W. Drexler, CARL ZEISS Meditec C; Femtolasers C.
  • Footnotes
    Support  FWF Y159PAT,CRAF1999–70549,NIH–RO1–EY11289–14,NIH–RO1–CA75289–04,NIH–RO1–EY13178–03,NIH–P30–EY13078
Investigative Ophthalmology & Visual Science May 2004, Vol.45, 2373. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      B. Hermann, A. Unterhuber, M. Wirtitsch, M. Stur, E. Ergun, C. Scholda, T. Ko, J.S. Schuman, J.G. Fujimoto, W. Drexler; Quantification Of Photoreceptor Layer Thickness Using Ultrahigh Resolution Optical Coherence Tomography . Invest. Ophthalmol. Vis. Sci. 2004;45(13):2373.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Abstract: : Purpose: To demonstrate in vivo quantification of the inner and outer photoreceptor layer thickness (PRLT) in the central foveal region by ultrahigh resolution optical coherence tomography (UHR OCT). Methods: A compact UHR OCT system has been developed enabling unprecedented visualization of intraretinal layers, especially the photoreceptor layer with 3 µm axial resolution. Normal subjects as well as selected patients with different macular pathologies were imaged and the inner and outer segment of the photoreceptors have been segmented and quantified. Results: Ultrahigh resolution OCT enables unprecedented in vivo identification of all major intraretinal layers. In normal subjects the central total PRLT was typically about 90 µm with about 45 µm thickness for both the photoreceptor inner and outer segments (IS, OS). At a distance of about 3 mm nasal, temporal, inferior and superior, the total PRLT decreases to about 50 µm with the photoreceptor IS being about 30 µm and the photoreceptor OS decreasing to about 20 µm. This is in accordance with the well–known increase in cone outer segment in the central foveal region. In patients with acute central serous chorioretinopathy, an increase in central total PRLT of typically up to 120 µm could be detected with UHR OCT, especially due to increased thickness of the photoreceptor OS. In patients with adult–onset foveal vitelliform dystrophy, central PRLT was up to 150 µm, whereas in patients with Stargardt dystrophy or retinitis pigmentosa, central PRLT of typically only 30 µm and 50 µm parafoveally were measured by UHR OCT. Conclusions: Enhanced visualization and precise quantification of the photoreceptor OS and photoreceptor IS have the potential for objective diagnosis of macular pathologies. Therefore, ultrahigh resolution ophthalmic OCT has the potential to enhance sensitivity for early ophthalmic diagnosis, as well as to contribute to a better under standing of ocular disease pathogenesis.

Keywords: imaging methods (CT, FA, ICG, MRI, OCT, RTA, SLO, ultrasound) • photoreceptors • retina 
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×