May 2003
Volume 44, Issue 13
Free
ARVO Annual Meeting Abstract  |   May 2003
Worldwide Accessible Comprehensive Visual Field Test & Diagnosis System
Author Affiliations & Notes
  • W. Fink
    NASA Jet Propulsion Laboratory/Caltech, Pasadena, CA, United States
  • A.A. Sadun
    Ophthalmology, Doheny Eye Institute, Keck School of Medicine at USC, Los Angeles, CA, United States
  • J.B. Clark
    NASA Johnson Space Center, Houston, TX, United States
  • Footnotes
    Commercial Relationships  W. Fink, Caltech P; A.A. Sadun, USC P; J.B. Clark, None.
  • Footnotes
    Support  NASA R&TD 01STCR-R.03.021.048
Investigative Ophthalmology & Visual Science May 2003, Vol.44, 55. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      W. Fink, A.A. Sadun, J.B. Clark; Worldwide Accessible Comprehensive Visual Field Test & Diagnosis System . Invest. Ophthalmol. Vis. Sci. 2003;44(13):55.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Abstract: : Purpose:To provide a worldwide accessible, comprehensive 3D threshold Amsler Grid test that allows for screening and examining people worldwide over the Internet and monitoring astronaut health in space. Further, to provide an automated, objective characterization of scotomas, offering a promising perspective towards modern computer-assisted diagnosis in medicine. Methods:We have created an Internet-deployable version of the 3D computer-automated threshold Amsler grid test, recently introduced by Fink (JPL/Caltech) and Sadun (Doheny/USC) (see http://www.wfbabcom5.com/wf335.htm). With one eye covered the patients are positioned at a fixed distance in front of a computer, equipped with either a touch-sensitive monitor or a regular monitor using a mouse. While focusing on a varying central fixation marker the patients trace with their finger/mouse the areas on an Amsler grid that are missing from their field of vision. Various degrees of contrast of the Amsler grid are presented by repeating the test at different greyscale levels. The results are recorded and transmitted via the Internet to a central server, where a topographical contour map, a 3D depiction of the central hill-of-vision, and a comprehensive scotoma characterization (area, volume, and slope distribution of visual field loss, etc.) are generated and sent back to the client. Results:The now Internet-deployable 3D computer-automated threshold Amsler grid test has proven, in multiple clinical studies, to be innovative and successful for fast (4 – 5 minutes per eye), easy (use of finger, touch pen, or mouse), accurate (spatial resolution 1 deg. to 15’), non-invasive, and comprehensive visual field testing. Conditions such as optic neuritis, AION, ARMD, glaucoma, and ocular hypertension have been successfully detected by the 3D visual field test. A software package has been developed for the automated, comprehensive evaluation of scotomas in 3D with respect to area of visual field loss as a function of contrast sensitivity, overall volume of visual field loss as compared to a "normal" hill-of-vision, and slope distribution of the scotoma boundaries. Conclusions:This Internet-deployable automated test & diagnosis system is a significant step towards screening and examining people worldwide, monitoring astronaut health in space, and to assist physicians, both on Earth and in space, with an independent second opinion or provide expertise where otherwise not readily available.

Keywords: visual fields • contrast sensitivity • perimetry 
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×