May 2003
Volume 44, Issue 13
Free
ARVO Annual Meeting Abstract  |   May 2003
Assessing Validity of Visual Field Clustering Schemes for Standard Perimetry Using Machine Learning Classifiers
Author Affiliations & Notes
  • C. Boden
    Hamilton Glaucoma Center and Visual Function Laboratory, Department of Ophthalmology, UCSD, UCSD, La Jolla, CA, United States
  • K. Chan
    Computational Neurobiology Laboratory, Salk Institute, La Jolla, CA, United States
  • M. Goldbaum
    Hamilton Glaucoma Center and Visual Function Laboratory, Department of Ophthalmology, UCSD, La Jolla, CA, United States
  • T. Lee
    Institute for Neural Computation & Computational Neurobiology Lab, UCSD, La Jolla, CA, United States
  • T. Sejnowski
    Institute for Neural Computation & Computational Neurobiology Lab, UCSD, La Jolla, CA, United States
  • J. Hao
    Institute for Neural Computation & Computational Neurobiology Lab, UCSD, La Jolla, CA, United States
  • C. Vasile
    Institute for Neural Computation & Computational Neurobiology Lab, UCSD, La Jolla, CA, United States
  • F.A. Medeiros
    Institute for Neural Computation & Computational Neurobiology Lab, UCSD, La Jolla, CA, United States
  • R.N. Weinreb
    Institute for Neural Computation & Computational Neurobiology Lab, UCSD, La Jolla, CA, United States
  • P.A. Sample
    Institute for Neural Computation & Computational Neurobiology Lab, UCSD, La Jolla, CA, United States
  • Footnotes
    Commercial Relationships  C. Boden, None; K. Chan, None; M. Goldbaum, None; T. Lee, None; T. Sejnowski, None; J. Hao, None; C. Vasile, None; F.A. Medeiros, None; R.N. Weinreb, Carl Zeiss Meditech F; P.A. Sample, Carl Zeiss Meditech F.
  • Footnotes
    Support  NIH Grants EY08208 (PAS), EY13928 (MHG), LM05759 (MHG)and Research to Prevent Blindness (PAS)
Investigative Ophthalmology & Visual Science May 2003, Vol.44, 60. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      C. Boden, K. Chan, M. Goldbaum, T. Lee, T. Sejnowski, J. Hao, C. Vasile, F.A. Medeiros, R.N. Weinreb, P.A. Sample; Assessing Validity of Visual Field Clustering Schemes for Standard Perimetry Using Machine Learning Classifiers . Invest. Ophthalmol. Vis. Sci. 2003;44(13):60.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Abstract: : Purpose: To evaluate the validity of 4 different visual field clustering schemes used to discriminate glaucomatous from healthy eyes by assessing their performance with machine learning classifiers. Methods: Commonly used schemes for clustering 24-2 visual field locations ("maps") were compared - Garway-Heath et al., Weber et al., Glaucoma Hemifield Test Sectors (GHTs) and GHT Difference (GHTd) maps. Glaucoma patients (156 eyes/156 patients) had IOP>23 mmHg and glaucomatous optic neuropathy by masked stereophotograph review. Normal controls (189 eyes/189 participants) had no history of elevated IOP and normal optic discs. Raw thresholds from standard perimetry Humphrey full-threshold field locations were averaged within each cluster ("cluster thresholds"), for all clusters within each map. Four types of statistical and machine classifiers [Linear Discriminant Function (LDF), constrained Mixture of Gaussian (cMoG) and Support Vector Machines (SVM linear; SVM gaussian)] were trained separately on each of the "maps" using cluster thresholds plus age,.and tested using cross-validation techniques. Results: Areas under the ROC curves ranged from 0.77±0.02 (GHTd with SVMl and LDF) to 0.93±0.01 (Garway-Heath with cMoG). Sensitivities for detection of GON at a specificity of 96%, for example, generally ranged from 0.50 (Garway-Heath with LDF) to 0.75 (Garway-Heath with cMoG), although GHTd with LDF and SVMl were lower with sensitivities of 0.35 and 0.33 respectively. Conclusions: All maps appear to aggregate the visual field locations with similar effectiveness. None of the maps reduce performance compared to a full set of 52 field locations1 and no single map outperformed the others. This suggests that the choice of map for comparison of the visual field with structural locations on the optic disc is open and determined by the needs of a particular study. 1 Goldbaum et. al.(2002), IOVS, 43, 162-9.

Keywords: perimetry • visual fields 
×
×

This PDF is available to Subscribers Only