May 2003
Volume 44, Issue 13
Free
ARVO Annual Meeting Abstract  |   May 2003
Pulsed Mid-IR Laser Trabeculoplasty Versus ALT in Cats
Author Affiliations & Notes
  • V. Fernandez
    Ophthal/ Biophysics Ctr, Bascom Palmer Eye Inst/U of Miami, Miami, FL, United States
  • J. Stoiber
    Ophthal/ Biophysics Ctr, Bascom Palmer Eye Inst/U of Miami, Miami, FL, United States
  • P.D. Lamar
    Ophthal/ Biophysics Ctr, Bascom Palmer Eye Inst/U of Miami, Miami, FL, United States
  • E. Hernandez
    Ophthal/ Biophysics Ctr, Bascom Palmer Eye Inst/U of Miami, Miami, FL, United States
  • N. Salas
    Ophthal/ Biophysics Ctr, Bascom Palmer Eye Inst/U of Miami, Miami, FL, United States
  • F. Manns
    Ophthal/ Biophysics Ctr, Bascom Palmer Eye Inst/U of Miami, Miami, FL, United States
  • F. Fantes
    Ophthal/ Biophysics Ctr, Bascom Palmer Eye Inst/U of Miami, Miami, FL, United States
  • J.M. Parel
    Ophthal/ Biophysics Ctr, Bascom Palmer Eye Inst/U of Miami, Miami, FL, United States
  • Footnotes
    Commercial Relationships  V. Fernandez, None; J. Stoiber, None; P.D. Lamar, None; E. Hernandez, None; N. Salas, None; F. Manns, None; F. Fantes, None; J.M. Parel, None.
Investigative Ophthalmology & Visual Science May 2003, Vol.44, 1176. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      V. Fernandez, J. Stoiber, P.D. Lamar, E. Hernandez, N. Salas, F. Manns, F. Fantes, J.M. Parel; Pulsed Mid-IR Laser Trabeculoplasty Versus ALT in Cats . Invest. Ophthalmol. Vis. Sci. 2003;44(13):1176.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Abstract: : Purpose:To comparatively assess the safety of two pulsed near IR lasers: Titanium Sapphire (Ti:Al2O3) and Alexandrite (BeAl2O4:Cr3+), 10µs pulse, λ ~790nm, versus conventional blue-green (λ = 488 + 514.5nm) Argon (Ar+) laser trabeculoplasty (ALT) in an animal model. Methods: The left eyes of 14 cats received a conventional 40 to 60 spots 180° treatment (right eye = control). The IR lasers pulse energy was varied over a broad range to study laser-tissue effects. 6 cats were treated with Titanium Sapphire (8 to 74 mJ/pulse, 175 µm spot), 3 with Alexandrite (11 to 53mJ/pulse, 200 µm spot), and 5 with Argon (400-1000mW @ 0.1 sec pulse duration, 50 µm spot). All animals received an extensive ocular examination (bilateral pachymetry & tonometry (Tonopen & pneumotonometer), slit-lamp & gonioscopy) 1hr postoperatively, at POD 1, 7 and weekly thereafter for 3 months. Scanning electron microscopy (SEM) was performed in selected eyes to evaluate potential alterations in the trabecular meshwork structure. Results: With all 3 lasers, the degree of depigmentation was a function of the pulse energy. Titanium Sapphire treated eyes that received high energy levels (>60mJ) displayed a slight inflammatory reaction, resolving within 24 hours. Eyes treated with the Argon presented a slight anterior chamber inflammation at 1 hr. The Alexandrite treated eyes showed moderate signs of inflammation with focal blood staining in the angle in 2 of the 3 cats, resolving within 1 week. IOP measurements using pneumotonometry under anesthesia resulted in more consistent readings compared to Tonopen. IOP at 1hr, 1 day and 7 day was remarkably lower in all animals, irrespective of the laser source used. Argon laser treated eyes returned to baseline IOP after 1 week, whereas after Alexandrite laser treatment decrease in IOP lasted for at least 2 weeks and after Titanium Sapphire laser treatment for at least 3 weeks. With time, Titanium Sapphire treated eyes revealed depigmentation that increased in size, some reaching confluence; with the alexandrite, depigmentation was much stronger whereas with the Argon the depigmentation regressed. On SEM no physical damage of the trabecular meshwork could be found in Titanium Sapphire treated eyes. Conclusions: Titanium Sapphire laser trabeculoplasty selectively altered cells at energies ~ 10mJ per shot and was found safe to eye structures. All three lasers used in this animal model were effective at initially lowering the IOP. Support: Florida Lions Eye Bank, SOLX Boston, Research to Prevent Blindness NY, Henri and Flore Lesieur Foundation, FWF Austrian Science Fund

Keywords: trabecular meshwork • laser • intraocular pressure 
×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×