Relationship Between Nocturnal Intraocular Pressure Variations and Sleep Macrostructure
Author Affiliations & Notes
  • Florent Aptel
    Université Grenoble Alpes, Grenoble, France
    Department of Ophthalmology, University Hospital, CHU Grenoble, Grenoble, France
    INSERM U1042, Lab Hypoxia and Physiopathology, Université Grenoble Alpes, Grenoble, France
  • Perrine Canaud
    Université Grenoble Alpes, Grenoble, France
    Department of Ophthalmology, University Hospital, CHU Grenoble, Grenoble, France
  • Renaud Tamisier
    Université Grenoble Alpes, Grenoble, France
    INSERM U1042, Lab Hypoxia and Physiopathology, Université Grenoble Alpes, Grenoble, France
  • Jean-Louis Pépin
    Université Grenoble Alpes, Grenoble, France
    INSERM U1042, Lab Hypoxia and Physiopathology, Université Grenoble Alpes, Grenoble, France
  • Benjamin Mottet
    Université Grenoble Alpes, Grenoble, France
    Department of Ophthalmology, University Hospital, CHU Grenoble, Grenoble, France
  • Ralitsa Hubanova
    Université Grenoble Alpes, Grenoble, France
    Department of Ophthalmology, University Hospital, CHU Grenoble, Grenoble, France
  • Jean-Paul Romanet
    Université Grenoble Alpes, Grenoble, France
    Department of Ophthalmology, University Hospital, CHU Grenoble, Grenoble, France
  • Christophe Chiquet
    Université Grenoble Alpes, Grenoble, France
    Department of Ophthalmology, University Hospital, CHU Grenoble, Grenoble, France
    INSERM U1042, Lab Hypoxia and Physiopathology, Université Grenoble Alpes, Grenoble, France
  • Correspondence: Florent Aptel, Department of Ophthalmology, University Hospital of Grenoble, 38043 Grenoble Cedex 09, France; [email protected]
Investigative Ophthalmology & Visual Science October 2015, Vol.56, 6899-6905. doi:https://doi.org/10.1167/iovs.15-17456
  • Views
  • PDF
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Florent Aptel, Perrine Canaud, Renaud Tamisier, Jean-Louis Pépin, Benjamin Mottet, Ralitsa Hubanova, Jean-Paul Romanet, Christophe Chiquet; Relationship Between Nocturnal Intraocular Pressure Variations and Sleep Macrostructure. Invest. Ophthalmol. Vis. Sci. 2015;56(11):6899-6905. https://doi.org/10.1167/iovs.15-17456.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose: The purpose of this study was to characterize the relationships between nocturnal intraocular pressure (IOP) variations and sleep macrostructure in healthy subjects.

Methods: This was a cross-sectional study conducted in a center with shared expertise in chronobiology. Twelve healthy volunteers (22.3 ± 2.3 years) underwent a 24-hour IOP measurement session. The IOP variations of one eye were continuously estimated using a contact lens sensor (CLS) measuring the changes in corneal curvature related to the IOP and not requiring nocturnal awakening for measurements. The CLS measurement characteristics (mean, maximum, minimum, and amplitude) were evaluated across sleep stages (non–rapid eye movement [NREM] sleep [N1, N2, N3], REM) and assessed using polysomnography. The CLS signal measurement changes during sleep stage changes were calculated to evaluate the effects of sleep on IOP.

Results: A 24-hour IOP nyctohemeral rhythm was found in all subjects. During the nocturnal period, IOP signal values were significantly lower during wake stages than during REM and NREM N1, N2, and N3 sleep stages (P ≤ 0.04). The IOP signal values were significantly higher during the REM stage than during the NREM stages (P ≤ 0.03) and progressively decreased as NREM sleep deepened (P ≤ 0.04). We found a positive relationship between the micro-arousal index and the nocturnal period CLS signal SD (r = 0.76; P = 0.024) and a negative relationship between sleep efficiency and the nocturnal period CLS signal SD (r = −0.69; P = 0.041).

Conclusions: Sleep micro- and macrostructure and nocturnal IOP variations are closely related in young subjects without sleep disorders. Across sleep stages, IOP is highest during REM sleep and progressively decreases as NREM sleep deepens.

Many physiologic parameters known to have an impact on intraocular pressure (IOP) levels and fluctuations vary across the different sleep stages: blood pressure, central venous pressure, heart and respiratory rate, body temperature, and sympathetic and parasympathetic nerve activity.16 All studies on sleep and related 24-hour or nocturnal IOP rhythms conducted to date have used repeated IOP measurements (hourly or less frequent IOP measurements) requiring nocturnal awakenings, thus potentially disturbing sleep structure, blood pressure dipping status,7 and sympathetic activity. These repetitive arousals actually prevented a continuously valid evaluation of the relationship between IOP variations and sleep micro- and macrostructure.812 
A contact lens sensor (CLS; SENSIMED Triggerfish; SENSIMED AG, Lausanne, Switzerland) was recently developed to continuously monitor IOP noninvasively over 24 hours in an ambulatory setting.1316 The measurement using this device is based on the assumption that a correlation exists between IOP and corneal curvature.5 We previously demonstrated that this new device is an accurate and reproducible method to characterize the 24-hour nyctohemeral IOP rhythm in young healthy subjects, although the CLS signal cannot be translated in absolute IOP expressed in millimeters of mercury at each point of the 24-hour session.1719 
The present study takes advantage of this new noninvasive method monitoring IOP fluctuations without induced arousals to evaluate the physiologic relationships between nocturnal IOP level variations and sleep micro- and macrostructure in healthy young subjects free of sleep disorders. 
Methods
Study Population
The protocol has been previously described in detail.1719 This prospective investigation was conducted in a university-affiliated hospital sleep laboratory, followed the tenets of the Declaration of Helsinki, and was approved by the local institutional review board (#8881). All participating subjects provided both verbal and written informed consent. Participants were paid for their time and effort. 
Twenty-four eyes of 12 healthy subjects were studied. Inclusion criteria were as follows: subjects free of sleep disorders, without endocrine illness or ocular disease (spherical equivalent between −1 and +1 diopter), with regular lifestyle habits and usual sleep duration lasting approximately 8 hours. The exclusion criteria were as follows: shift workers, having taken a transmeridian flight less than 2 months before the beginning of the study, any medical treatment, and tobacco smokers. 
At the inclusion visit, all study participants underwent a complete ophthalmic examination (including refraction, biomicroscopy, Goldmann applanation tonometry, gonioscopy, fundus examination, and ultrasound pachymetry [Pocket II pachymeter; Quantel Medical, Clermont-Ferrand, France]). All subjects also filled out a general health questionnaire and underwent a complete physical examination. The eyes studied were randomized when both were eligible. 
IOP Measurements
The CLS (Triggerfish; SENSIMED AG) is a highly oxygen-permeable soft contact lens whose key elements are two sensing-resistive strain gauges that are capable of recording circumferential changes in the area of the corneoscleral junction. The contact lens (diameter, 14.1 mm; thickness, 585 μm at the center and 260 μm at the edge) exists in three different base curves: steep, medium, and flat, with, respectively, an 8.4-, 8.7-, and 9-mm curvature radius. Ten data points/s are acquired during a 30-second measurement period, repeated every 5 minutes. The output of the sensor is expressed in electric arbitrary units (eqVm). 
Polysomnography
Continuous recordings were taken with the electrode positions C3/A2-C4/A1-Cz/01 of the International 10-20 System of Electrode Placement measuring eye movements, a chin electromyogram, and an ECG with a modified V2 lead. Sleep was scored manually according to standard criteria.20 Air flow was measured with nasal pressure associated with the sum of buccal and nasal thermistor signals. Respiratory effort was monitored with abdominal and thoracic bands. Oxygen saturation was measured using a pulse oximeter. 
Experimental Sessions
Subjects maintained a self-selected constant sleep-wake schedule (onset between 10 PM and 12 AM and wake-up between 7 AM and 8 AM) 2 weeks before and during the study, checked by sleep–wake diaries and by ambulatory actigraphy monitoring using a wrist accelerometer Actiwatch (CamNtech, Cambridge, UK). During the experimental sessions, they were requested not to drink alcohol- and caffeine-containing beverages. Although the patients were housed in the hospital, they were allowed to have free activities during the diurnal period of the 24-hour session (9 AM to 10 PM). Subjects were asked to go to bed at 10 PM and were asked to get up at 8 AM. 
Statistical Analysis
From raw IOP data over 24 hours, a nonlinear least-square, dual-harmonic regression analysis was used to model the 24-hour IOP rhythms as  where A1 is the amplitude of the fundamental cosine fit, A2 is the amplitude of the first harmonic cosine fit, Φ1 is the acrophase of the fundamental cosine fit, Φ2 is the acrophase of the first harmonic cosine fit, τ is the endogenous circadian period (set at 24 hours due to entrained conditions), M is midline estimating statistic of rhythm (MESOR), and t is time. Unbiased estimates and confidence limits of amplitude (half the difference between the highest and lowest IOP values in a 24-hour cycle), MESOR (M; average IOP values in a 24-hour cycle), acrophase (time of the highest IOP value in a 24-hour cycle), and bathyphase (time of the lowest IOP value in a 24-hour cycle) were obtained from modeling each IOP curve.21,22  
The CLS measurement characteristics (mean signal, maximum signal, minimum signal, and amplitude) were evaluated across sleep stages (non–rapid eye movement [NREM] sleep [N1, N2, N3] and REM). The CLS signal measurement changes during sleep stage changes were calculated to evaluate the effects of sleeping or awakening on IOP. The relationship between the micro-arousal index, sleep efficiency (total sleep time per sleep period), and the nocturnal period CLS signal SD was examined to evaluate the influence of sleep quality and fragmentation on nocturnal IOP fluctuations. 
The skewness-kurtosis normality test was used to assess the normality of the measurements. The paired Student's t-test and ANOVA were used to compare means and percentages. McNemar χ2 tests were used for the analysis of dichotomous variables. Correlations were evaluated using the Pearson correlation coefficient. Data analyses were performed using SPSS (Statistical Package for the Social Sciences, version 17.0; SPSS, Inc., Chicago, IL, USA) and R software (version 2.14; R Foundation for Statistical Computing, Vienna, Austria). 
Results
Subject Characteristics
Twelve healthy Caucasian subjects (24 eyes) were included (eight women and four men; 22.3 ± 2.3 years old; body mass index, 20.8 ± 2.0 kg/m2). All subjects were easily fitted with the Triggerfish CLS (nine medium lenses, two steep, and one flat, depending on keratometry) on one randomly selected eye (six left eyes and six right eyes). At inclusion, mean IOP values using Goldmann applanation tonometry were 13.8 ± 2.1 mm Hg on the right eye and 13.7 ± 1.9 mm Hg on the left eye (P = 0.9). Total sleep time (TST, total of NREM [N1, N2, N3] and REM sleep in a period), total sleep period (TSP, period of time measured from sleep onset to final awakening), sleep efficiency (TST/TSP), sleep architecture with absolute and percentage of time spent awake after sleep onset (WASO), NREM (N1, N2, and N3) and REM sleep, number of cycles per night, and the micro-arousal index are displayed in Table 1
Table 1
 
Sleep Duration, Quality, and Architecture With Absolute and Relative NREM (N1, N2, and N3) and REM Sleep Stage Duration and Percentages of Total Sleep Time
Table 1
 
Sleep Duration, Quality, and Architecture With Absolute and Relative NREM (N1, N2, and N3) and REM Sleep Stage Duration and Percentages of Total Sleep Time
Intraocular Pressure and Sleep Stages
The minimum, maximum, amplitude, and mean signal values of the population during the 24-hour and the diurnal periods and during each sleep stage of the sleep period (wake NREM N1, N2, N3, and REM) are summarized in Table 2. All subjects had a nocturnal acrophase (3:51 AM ± 43 minutes; range, 3:26 AM to 4:12 AM) and a diurnal bathyphase (2:30 PM ± 34 minutes; range, 2:12 PM to 2:48 PM). 
Table 2
 
Contact Lens Sensor Signal Measurement Characteristics: Minimum, Maximum, and Mean Signal Values and Amplitude
Table 2
 
Contact Lens Sensor Signal Measurement Characteristics: Minimum, Maximum, and Mean Signal Values and Amplitude
The relationship between the sleep stages and the IOP signal values was evaluated using ANOVA. We found a significant relationship between the sleep stages and the IOP signal values (P = 0.02). Follow-up multiple post hoc pairwise comparisons were then performed to compare the different groups. The significance level was not adjusted for those post hoc comparisons, given that an ANOVA test was performed first and showed a significant relationship. We compared the IOP values during awakening and during various sleep stages. The IOP signal values were significantly lower during awakening than during REM and NREM N1, N2, and N3 stages (P = 0.04, 0.02, 0.01, and 0.01, respectively). We compared the IOP values during the REM stage and the NREM stages. The IOP signal values were significantly higher during the REM stage than during the NREM N1, N2, and N3 stages (P = 0.03, 0.02, and 0.018, respectively). Finally, the IOP values were compared during the slow-wave N3 stage to the N1 and N2 NREM stages. The IOP signal values were significantly higher during NREM N1 and N2 stages than during the NREM N3 stages (P = 0.04 and 0.02, respectively). Figure 1 shows the 24-hour raw and modeled individual IOP curves of two subjects and illustrates that IOP follows a nyctohemeral rhythm in young healthy subjects and was lower during the diurnal period and higher during the nocturnal period. 
Figure
 
(A, B) Examples of 24-hour raw and modeled individual IOP curves of two subjects. The IOP is expressed in eqVm.
Figure
 
(A, B) Examples of 24-hour raw and modeled individual IOP curves of two subjects. The IOP is expressed in eqVm.
Intraocular Pressure Changes Across Sleep Stages
The CLS signal measurement changes from one sleep stage to another are summarized in Table 3. The CLS signal significantly increased when moving from wake to REM and NREM N1 and N2 stages (P = 0.004, 0.03, and 0.04, respectively). The CLS signal significantly increased when going from NREM N2 and N3 stages to REM stages (P = 0.018 and 0.028, respectively). The CLS signal significantly decreased when going from REM to wake (P = 0.027) and from NREM N1, N2, and N3 stages to wake (P = 0.04, 0.038, and 0.021, respectively). 
Table 3
 
Contact Lens Sensor Signal Measurement Changes During Sleep Stage Changes
Table 3
 
Contact Lens Sensor Signal Measurement Changes During Sleep Stage Changes
Table 4
 
CLS Signal Measurement Changes During Sleeping/Awakening
Table 4
 
CLS Signal Measurement Changes During Sleeping/Awakening
The CLS signal measurement changes during the night are summarized in Table 2. We found a significant negative relationship between changes in sleep stages and changes in CLS values, indicating that CLS values increase during sleeping (i.e., negative changes in sleep stages) and decrease during awakening (i.e., positive changes in sleep stages; P = 0.026). 
Intraocular Variability and Sleep Quality
We found a significant positive relationship between the micro-arousal index and the nocturnal period CLS signal SD (r = 0.76, P = 0.024) and a significant negative relationship between sleep efficiency (total sleep time per sleep period) and the nocturnal period CLS signal standard deviation (r = −0.69, P = 0.041). 
Discussion
Using an innovative continuous IOP measurement that does not disturb sleep, we evaluated the physiologic relationships between nocturnal IOP levels and variations and sleep quality and structure in healthy subjects. We found that during the nocturnal period, the IOP was lower during awakening than during REM and NREM N1, N2, and N3 sleep stages. Among the sleep stages, IOP was higher during the REM stage and progressively decreased with deepening of NREM sleep. We found a higher variability in nocturnal IOP in subjects with the highest micro-arousal index and the lowest sleep efficiency. 
Only two previous studies have assessed the relationships between sleep macrostructure and IOP levels and fluctuations.8,10 
The first one was conducted in 12 young and 12 older healthy subjects.8 During a 24-hour period, IOP was measured hourly with a Tono-Pen electronic tonometer (Oculab, Glendale, CA, USA). Nocturnal polysomnography was performed. The IOP was lower during wakefulness (14.9 ± 0.1 mm Hg) than during light sleep (16.6 ± 0.3 mm Hg), slow-wave sleep (17.0 ± 0.4 mm Hg), and REM sleep (16.0 ± 0.3 mm Hg). The difference in IOP between slow-wave and REM sleep was significant (P = 0.03). However, it should be noted that subjects were awakened hourly for IOP measurements. Oxybuprocaine eye drops were administered before IOP measurements, and series of three to six measurements were repeated until the intermeasure variability was less than 5%. For these reasons, the authors reported a duration of IOP measurement longer than 1 minute (81.4 ± 2.1 and 85.3 ± 3.6 seconds in young and older subjects, respectively). The mean delay for returning to sleep after IOP measurements was rather long: 198.5 ± 15.2 and 521.0 ± 85.4 seconds in young and older subjects, respectively. Moreover, in this study, IOP was not strictly speaking measured during sleep, but immediately after awakening. Another reason that could explain the differences with our study is that only six to nine nocturnal IOP measurements were taken for each subject depending on sleep duration (hourly measurements). Because this was not sufficient to obtain several IOP values during each of the sleep stages for each subject, the data from all subjects were pooled before comparing IOP values among sleep stages. In one individual subject, it was not possible to compare the IOP levels or variations among sleep stages, nor to evaluate the IOP changes when going from one sleep stage to another. By contrast, in our study, 3600 data points were acquired every hour, making it possible to obtain thousands of IOP values for each of the subjects' sleep stages and to make intraindividual paired comparisons. 
The second study conducted by the same team using a similar design assessed 16 healthy young African volunteers and 11 young African open-angle glaucoma patients.10 During a 24-hour period, IOP was measured hourly with a Modular One pneumatonometer (Modular One; Digilab, Cambridge, MA, USA). Nocturnal polysomnography was performed. The IOP was also lower during wakefulness than during light sleep, slow-wave sleep, and REM sleep. The variations in IOP were lowest during REM sleep and highest during slow-wave sleep. This study, however, has the same limitations as the above-mentioned study, which we believe could explain that the IOP and IOP variations were found lower during the REM sleep than during the slow-wave sleep, whereas we found the opposite. 
Many ocular or systemic factors involved during the sleep stages could explain the higher IOP levels during REM sleep and the wake state than during NREM stages. 
Local Factors
Studies have shown that blinking and eye movements could increase IOP.23,24 Blinking and eye movements are frequent during the REM sleep stages and micro-arousals and by contrast much less frequent during the NREM sleep stages, particularly during the deep slow-wave NREM sleep stages. 
Systemic Factors
Studies have found that compared with wake and REM sleep, NREM sleep is characterized by a predominance of vagal parasympathetic activity, with a decline in sympathetic activity that is most pronounced in slow-wave sleep.7,25 Consequently, blood pressure, central venous pressure, and the heart and respiratory rates decrease throughout NREM sleep, particularly during slow-wave sleep. This physiologic context could explain that we found that IOP continuously decreases with the progressive deepening of NREM sleep. By contrast, studies have demonstrated that in REM sleep, sympathetic activity increases significantly and is highly variable.7,25,26 Consequently, blood pressure and heart rate are higher and highly changeable. This could also explain that we found a significantly higher IOP during the REM sleep compared with the NREM sleep. 
The findings of the present study have important implications for physiologic knowledge and clinical relevance. 
Given that the NREM sleep is prominent at the beginning of the night, whereas the duration of the REM sleep increases during the last sleep cycles, the findings of the present study could explain that the acrophase of the IOP 24-hour variation occurs in the second part of the night or in the early morning just before awakening in a vast majority of healthy subjects.810,12,17,19 
The finding that the nocturnal regulation of IOP is related to sleep characteristics could suggest that sleep disorders affect the nyctohemeral and nocturnal rhythms of IOP and increase the nocturnal variability of IOP. Numerous studies have evaluated the relationships between glaucoma and sleep apnea, and the association between glaucoma and sleep apnea is still debated.27 Further studies should also evaluate the impact of other disturbances in sleep quality and quantity on 24-hour and nocturnal IOP and, in turn, ocular diseases. 
In a recent study, a customized algorithm developed by the manufacturer of the device allowing to detect and quantify eye blinks and to identify wake and sleep periods (REM and NREM) from the signal recorded was presented.28 Because the algorithm used in this study was a customized algorithm but is not yet commercially available, we did not detect eye blinks and identify wake and sleep periods from the CLS signal in the present study. As taking a measurement only with the CLS is much more convenient for the patient than undergoing a complete polysomnography, it would be interesting to compare the results of sleep studies and the results of sleep evaluation provided by this new algorithm in future studies. 
In conclusion, we found that sleep micro- and macrostructure and nocturnal regulation of IOP are related in young healthy humans. During the nocturnal period, IOP is lower during the wake stages than during the REM and NREM N1, N2, and N3 stages. Among sleep stages, IOP is higher during the REM stage and continuously decreases with the progressive deepening of NREM sleep. Intraocular pressure is highly variable in subjects with poor sleep quality. These data open new avenues in research and prompt to evaluate sleep quality and quantity in clinical studies in patients with ocular hypertension or glaucoma. 
Acknowledgments
Supported by the Association de Recherche et de Formation en Ophtalmologie and the Fondation de l'Avenir. The funding organizations had no role in the design and conduct of the study; had no role in collection, management, analysis, and interpretation of the data; and had no role in preparation, review, or approval of the manuscript. The authors alone are responsible for the content and writing of the paper. 
Disclosure: F. Aptel, None; P. Canaud, None; R. Tamisier, None; J.-L. Pépin, None; B. Mottet, None; R. Hubanova, None; J.-P. Romanet, None; C. Chiquet, None 
References
Shapiro A, Shoenfeld Y, Konikoff F, Udassin R, Shapiro Y. The relationship between body temperature and intraocular pressure. Ann Ophthalmol. 1981 ; 13: 159 –1.
Castejon H, Chiquet C, Savy O, et al. Effect of acute increase in blood pressure on intraocular pressure in pigs and humans. Invest Ophthalmol Vis Sci. 2010 ; 51: 1599 –1.
Cooper RL, Beale DG, Constable IJ, Grose GC. Continual monitoring of intraocular pressure: effect of central venous pressure respiration, and eye movements on continual recordings of intraocular pressure in the rabbit, dog, and man. Br J Ophthalmol. 1979 ; 63: 799–804.
Reitsamer HA, Kiel JW. A rabbit model to study orbital venous pressure intraocular pressure, and ocular hemodynamics simultaneously. Invest Ophthalmol Vis Sci. 2002 ; 43: 3728 –37.
Bakke EF, Hisdal J, Semb SO. Intraocular pressure increases in parallel with systemic blood pressure during isometric exercise. Invest Ophthalmol Vis Sci. 2009 ; 50: 760 –76.
Karabatakis VE, Natsis KI, Chatzibalis TE, et al. Correlating intraocular pressure, blood pressure, and heart rate changes after jogging. Eur J Ophthalmol. 2004 ; 14: 117 –1.
Pepin JL, Borel AL, Tamisier R, Baguet JP, Levy P, Dauvilliers Y. Hypertension and sleep: overview of a tight relationship. Sleep Med Rev. 2014 ; 18: 509–519.
Buguet A, Py P, Romanet JP. 24-hour (nyctohemeral) and sleep-related variations of intraocular pressure in healthy white individuals. Am J Ophthalmol. 1994 ; 117: 342–347.
Liu JH, Kripke DF, Hoffman RE, et al. Nocturnal elevation of intraocular pressure in young adults. Invest Ophthalmol Vis Sci. 1998 ; 39: 2707–2712.
Noël C, Kabo AM, Romanet JP, Montmayeur A, Buguet A. Twenty-four-hour time course of intraocular pressure in healthy and glaucomatous Africans: relation to sleep patterns. Ophthalmology. 2001 ; 108: 139 –1.
Liu JH, Zhang X, Kripke DF, Weinreb RN. Twenty-four-hour intraocular pressure pattern associated with early glaucomatous changes. Invest Ophthalmol Vis Sci. 2003 ; 44: 1586–1590.
Liu JH, Bouligny RP, Kripke DF, Weinreb RN. Nocturnal elevation of intraocular pressure is detectable in the sitting position. Invest Ophthalmol Vis Sci. 2003 ; 44: 4439 –44.
Leonardi M, Leuenberger P, Bertrand D, Bertsch A, Renaud P. First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens. Invest Ophthalmol Vis Sci. 2004 ; 45: 3113–3117.
Leonardi M, Pitchon EM, Bertsch A, Renaud P, Mermoud A. Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes. Acta Ophthalmol. 2009 ; 87: 433–437.
Mansouri K, Shaarawy T. Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma. Br J Ophthalmol. 2011 ; 95: 627–629.
Mansouri K, Liu JH, Weinreb RN, Tafreshi A, Medeiros FA. Analysis of continuous 24-h intraocular pressure patterns in glaucoma. Invest Ophthalmol Vis Sci. 2012 ; 53: 8050 –805.
Mottet B, Aptel F, Romanet JP, Hubanova R, Pépin JL, Chiquet C. 24-hour intraocular Pressure rhythm in young healthy subjects evaluated with continuous monitoring using a contact lens sensor. JAMA Ophthalmol. 2013 ; 131: 1507 –15.
Hubanova R, Aptel F, Chiquet C, Mottet B, Romanet JP. Effect of overnight wear of the Triggerfish(®) sensor on corneal thickness measured by Visante(®) anterior segment optical coherence tomography. Acta Ophthalmol. 2014 ; 92: 119 –1.
Aptel F, Tamisier R, Pépin JL, et al. Hourly awakening vs continuous contact lens sensor measurements of 24-hour intraocular pressure: effect on sleep macrostructure and intraocular pressure rhythm. JAMA Ophthalmol. 2014 ; 132: 1232 –123.
Berry RB, Budhiraja R, Gottlieb DJ, et al. Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine. J Clin Sleep Med. 2012 ; 8: 597–619.
Brown EN, Czeisler CA. The statistical analysis of circadian phase and amplitude in constant-routine core-temperature data. J Biol Rhythms. 1992 ; 7: 177–202.
Gronfier C, Wright KP,Jr, Kronauer RE, Czeisler CA. Entrainment of the human circadian pacemaker to longer-than-24-h days. Proc Natl Acad Sci U S A. 2007 ; 104: 9081–9086.
Green K, Luxenberg MN. Consequences of eyelid squeezing on intraocular pressure. Am J Ophthalmol. 1979 ; 88: 1072 –107.
Campbell DG, Schertzer RM. Pathophysiology of pigment dispersion syndrome and pigmentary glaucoma. Curr Opin Ophthalmol. 1995 ; 6: 96–101.
Lombardi F, Parati G. An update on: cardiovascular and respiratory changes during sleep in normal and hypertensive subjects. Cardiovasc Res. 2000 ; 45: 200 –2.
Somers VK, Dyken ME, Mark AL, Abboud FM. Sympathetic-nerve activity during sleep in normal subjects. N Engl J Med. 1993 ; 328: 303 –30.
Aptel F, Chiquet C, Tamisier R, et al. Association between glaucoma and sleep apnea in a large French multicenter prospective cohort. Sleep Med. 2014 ; 15: 576 –5.
Gisler C, Ridi A, Hennebert J, Weinreb RN, Mansouri K. Automated detection and quantification of circadian eye blinks using a contact lens sensor. Transl Vis Sci Technol. 2015 ; 4 (1): 4.
Figure
 
(A, B) Examples of 24-hour raw and modeled individual IOP curves of two subjects. The IOP is expressed in eqVm.
Figure
 
(A, B) Examples of 24-hour raw and modeled individual IOP curves of two subjects. The IOP is expressed in eqVm.
Table 1
 
Sleep Duration, Quality, and Architecture With Absolute and Relative NREM (N1, N2, and N3) and REM Sleep Stage Duration and Percentages of Total Sleep Time
Table 1
 
Sleep Duration, Quality, and Architecture With Absolute and Relative NREM (N1, N2, and N3) and REM Sleep Stage Duration and Percentages of Total Sleep Time
Table 2
 
Contact Lens Sensor Signal Measurement Characteristics: Minimum, Maximum, and Mean Signal Values and Amplitude
Table 2
 
Contact Lens Sensor Signal Measurement Characteristics: Minimum, Maximum, and Mean Signal Values and Amplitude
Table 3
 
Contact Lens Sensor Signal Measurement Changes During Sleep Stage Changes
Table 3
 
Contact Lens Sensor Signal Measurement Changes During Sleep Stage Changes
Table 4
 
CLS Signal Measurement Changes During Sleeping/Awakening
Table 4
 
CLS Signal Measurement Changes During Sleeping/Awakening
×
×