September 2016
Volume 57, Issue 12
Open Access
ARVO Annual Meeting Abstract  |   September 2016
Measurement of macular hole dimensions by OCT shadowgraphy
Author Affiliations & Notes
  • Saruban Pasu
    Moorfields Eye Hopsital, London, United Kingdom
  • Preena Tanna
    Moorfields Eye Hopsital, London, United Kingdom
  • James W B Bainbridge
    Moorfields Eye Hopsital, London, United Kingdom
  • Footnotes
    Commercial Relationships   Saruban Pasu, None; Preena Tanna, None; James Bainbridge, None
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science September 2016, Vol.57, 4252. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Saruban Pasu, Preena Tanna, James W B Bainbridge; Measurement of macular hole dimensions by OCT shadowgraphy. Invest. Ophthalmol. Vis. Sci. 2016;57(12):4252.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : The dimensions of a macular hole can help predict the outcome of intervention. The extent of the ellipsoid defect and base diameter can be measured by manual delineation in serial scans. We sought to investigate whether these dimensions are more readily indicated by the Topcon OCT shadowgram.

Methods : In OCT scans of 50 eyes with idiopathic full-thickness macular holes, we correlated the linear dimensions of OCT sections with those of the shadowgram. We measured the diameter of the total ellipsoid defect, the horizontal extent of intraretinal cysts and the base diameter of the hole using the calliper tool on the OCT section. We measured the linear horizontal diameter of the outer and inner edges of the shadowgram using ImageJ.

Results : The mean base diameter was 920 μm, and the mean ellipsoid defect was 2338 μm. The diameter of the total ellipsoid defect was correlated positively with the horizontal extent of intraretinal cysts (R2 = 0.67). The horizontal diameter of the outer edge of the shadowgram correlated positively with both the ellipsoid defect (R2 = 0.64) and the extent of intraretinal cysts (R2 = 0.76). The linear horizontal length of the inner edge of the shadowgram correlated positively with the base diameter of the hole (R2 = 0.64).

Conclusions : The dimensions of the inner and outer edges of the shadowgram provide a potentially useful indication of the dimensions of the base diameter of the hole and the extent of the ellipsoid defect respectively.

This is an abstract that was submitted for the 2016 ARVO Annual Meeting, held in Seattle, Wash., May 1-5, 2016.

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×