Normal and Cataract Crystalline Lens Evaluation with Swept-Source Optical Coherence Tomography
Author Affiliations & Notes
  • Alberto De Castro
    Laboratorio de Óptica, Universidad de Murcia, Murcia, Murcia, Spain
  • Antonio Benito
    Laboratorio de Óptica, Universidad de Murcia, Murcia, Murcia, Spain
  • Silvestre Manzanera
    Laboratorio de Óptica, Universidad de Murcia, Murcia, Murcia, Spain
  • Juan Mompean
    Laboratorio de Óptica, Universidad de Murcia, Murcia, Murcia, Spain
  • Belen Canizares
    Servicio de Oftalmología, Hospital Virgen de la Arrixaca, Murcia, Murcia, Spain
  • Jose Maria Marin
    Servicio de Oftalmología, Hospital Virgen de la Arrixaca, Murcia, Murcia, Spain
  • Ireneusz Grulkowski
    Faculty of Physics, Nicolaus Copernicus University, Torun, Poland
  • Pablo Artal
    Laboratorio de Óptica, Universidad de Murcia, Murcia, Murcia, Spain
  • Footnotes
    Commercial Relationships   Alberto De Castro, None; Antonio Benito, None; Silvestre Manzanera, None; Juan Mompean, None; Belen Canizares, None; Jose Maria Marin, None; Ireneusz Grulkowski, None; Pablo Artal, None
  • Footnotes
    Support  European Research Council Advanced Grant ERC-2013-AdG-339228 (SEECAT); SEIDI, Spain (grant FIS2013-41237-R); Polish Ministry of Science and Higher Education (IUVENTUS PLUS; IP2014 014073); “Fundación Séneca” Murcia, Spain (Grant 19897/GERM/15)
Investigative Ophthalmology & Visual Science June 2017, Vol.58, 2712. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Alberto De Castro, Antonio Benito, Silvestre Manzanera, Juan Mompean, Belen Canizares, Jose Maria Marin, Ireneusz Grulkowski, Pablo Artal; Normal and Cataract Crystalline Lens Evaluation with Swept-Source Optical Coherence Tomography. Invest. Ophthalmol. Vis. Sci. 2017;58(8):2712.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : To characterize different spatial structures appearing in the crystalline lens of older adults and cataract patients when imaged three dimensionally with a Swept Source Optical Coherence Tomography (OCT).

Methods : We used a laboratory prototype of high speed Swept Source OCT operating at 1050 nm for long-range imaging designed for full anterior segment visualization. The instrument itself and the processing parameters were optimized to enhance the image quality of the crystalline lens. Volumetric data consisted on 50 B-scans of 1900 A-scans each covering an area of 8x8 mm2. The anterior segment of both eyes in two age grouped subjects (young group, N=10, age range 13 to 44, mean 32; older adult group N=12, age range 62 to 91, mean 72 years old) was imaged. Within the older adult group, 8 subjects had visual complaints related to cataracts and were clinically graded according to the Lens Opacification Classification System III (LOCS III). The location in the meridional plane, the depth and the size of the structures visible in some of the crystalline lenses were studied.

Results : In the images of the crystalline lenses in the young group, the nucleus and several layers of the cortex were clearly visible. When the clinical examination revealed some opacity (nonzero LOCS III punctuation) in the cortex, structures were visible in the OCT images. Similar structures were also visible in some eyes of the older adult group that did not have any visual complains. In 8 of the 22 crystalline lenses imaged in the older adult group, hyperreflective structures were visible between two layers on both the anterior and posterior cortex. With respect to the pupil plane, this hyperreflective structures were crescent-shaped and tended to accumulate on the lower part starting in the vertical meridian between 1 and 1.5 mm away from the center of the pupil. Hyporeflective localized defects were visible in 4 lenses in the older adult group in either the anterior or the posterior cortex. These defects, whose size was about 1 mm wide, 200 μm deep, created shadows that blocked the pass of the OCT light.

Conclusions : Our swept-source OCT instrument permits to acquire 3-D information of the crystalline lens in vivo that reveals the position and size of the opacifications. This may allow a more detailed study of the age-related changes of the lens leading to clinically significant cataracts.