Using a bot script to bulk export Spectralis OCT scan measurements into a clinical data warehouse
Author Affiliations & Notes
  • Karsten Ulrich Kortuem
    Ophthalmology, Ludwig-Maximilians-University, Munich, Germany
    Moorfields Eye Hospital, London, United Kingdom
  • Johannes Schiefelbein
    Ophthalmology, Ludwig-Maximilians-University, Munich, Germany
  • Diana Jeliazkova
    Ophthalmology, Ludwig-Maximilians-University, Munich, Germany
  • Pearse Andrew Keane
    Moorfields Eye Hospital, London, United Kingdom
  • Christoph Kern
    Ophthalmology, Ludwig-Maximilians-University, Munich, Germany
  • Michael Müller
    Ophthalmology, Ludwig-Maximilians-University, Munich, Germany
  • Wolfgang J. Mayer
    Ophthalmology, Ludwig-Maximilians-University, Munich, Germany
  • Siegfried Priglinger
    Ophthalmology, Ludwig-Maximilians-University, Munich, Germany
  • Daniel Nasseh
    Institute for Biometry and Epidemiology, Ludwig-Maximilians-University, Munich, Germany
  • Footnotes
    Commercial Relationships   Karsten Kortuem, Allergan (C), Bayer (F), Bayer (C), Google (C), Novartis (F), Novartis (C), Zeiss (C); Johannes Schiefelbein, None; Diana Jeliazkova, None; Pearse Keane, Allergan (R), Bayer (R), Google (C), Haag-Streit (R), Heidelberg (R), Novartis (R), Novartis (C), Topcon (R); Christoph Kern, None; Michael Müller, None; Wolfgang Mayer, Alcon (F), Alcon (C), Heidelberg Engineering (R), Novartis (C), Oculentis (C), Polytech/Domilens (R), Zeiss Meditec (F), Zeiss Meditec (C), Ziemer (F), Ziemer (C); Siegfried Priglinger, None; Daniel Nasseh, None
  • Footnotes
    Support  Partly funded by Bayer and Novartis
Investigative Ophthalmology & Visual Science June 2017, Vol.58, 674. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Karsten Ulrich Kortuem, Johannes Schiefelbein, Diana Jeliazkova, Pearse Andrew Keane, Christoph Kern, Michael Müller, Wolfgang J. Mayer, Siegfried Priglinger, Daniel Nasseh; Using a bot script to bulk export Spectralis OCT scan measurements into a clinical data warehouse. Invest. Ophthalmol. Vis. Sci. 2017;58(8):674.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : As data warehouses with data from electronic health records (EHR) provide benefits for clinical research, adding information from imaging devices (e.g. retinal thickness from OCT) is useful. To overcome limitations in bulk exporting OCT measurements in device software, we implemented a bot script, which emulates mouse and keyboard strokes, to gather this data. To check accuracy of automatic OCT segmentation in our sample, we compared the measurements with manually segmented and exported OCT scans.

Methods : Since OCT devices often not come with a batch export function of aggregated information, a robotic script was implemented in Java utilizing the java.awt.Robot package running on 2 desktop PCs at the same time. The script used image recognition techniques (based on pixel colour values) to identify specific types of OCT data and consequently adapt its behavior and start a type-specific export process based on a sequence of mouse clicks and keyboard strokes. Exported XML files were added to our smart eye database using an individual developed Java based routine. Manual segmentation and export of 7077 OCT (Spectralis OCT, Heidelberg Engineering, Germany) volume scans of patients under active Anti-VEGF treatment was performed.

Results : 72.894 OCT scans were exported and stored in the data warehouse. The initial export process took about 60 full days. The ETDRS grid within the software was changed in 11% of cases from its default position by 7.5 pixel (SD +/-53.1pixel) in automatically segmented scans vs. in 82.9% of manually segmented cases by 32.5 pixel (63.9 pixel). The average Central retinal thickness (CRT) was 344.8 um (+/- 173.6) (manually segmented) vs. 341.2 um (+/- 138.4) (automatic segmented). Figure 1 shows a Bland-Altman plot of OCT scans of 600um or less in the uncorrected export.

Conclusions : Batch exporting OCT scans using a bot script is a possible way, if not provided in the device’s software. We achieved export in a relatively short time compared to manually triggered export. In a certain range of uncorrected CRT (200-400 um), most automatic segmentation done was precise. New technologies like deep learning may overcome the issue of malsegmentation and provide better results in thickened retinas.

This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017.

 

Bland-Altman plot of the two measurements for the corrected and uncorrected segmentation

Bland-Altman plot of the two measurements for the corrected and uncorrected segmentation

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×