Visual simulations of real multifocal lenses in a multi-channel Adaptive Optics system
Author Affiliations & Notes
  • Susana Marcos
    Instituto de Optica, CSIC, Madrid, Spain
  • Maria Vinas
    Instituto de Optica, CSIC, Madrid, Spain
  • Clara Benedi
    Instituto de Optica, CSIC, Madrid, Spain
  • Sara Aissati
    Instituto de Optica, CSIC, Madrid, Spain
  • Vyas Akondi
    Instituto de Optica, CSIC, Madrid, Spain
  • Xoana Barcala
    Instituto de Optica, CSIC, Madrid, Spain
  • Enrique Gambra
    Instituto de Optica, CSIC, Madrid, Spain
  • Footnotes
    Commercial Relationships   Susana Marcos, 2Eyes Vision (F), CSIC (P); Maria Vinas, 2EyesVision (I); Clara Benedi, None; Sara Aissati, None; Vyas Akondi, 2EyesVision (I); Xoana Barcala, None; Enrique Gambra, 2Eyes Vision (E)
  • Footnotes
    Support  ERC-2011-AdG 294099; FIS2014-56643-R; H2020 COFUND Marie Curie 291820; ERC-PoC SimVisSim
Investigative Ophthalmology & Visual Science June 2017, Vol.58, 1248. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Susana Marcos, Maria Vinas, Clara Benedi, Sara Aissati, Vyas Akondi, Xoana Barcala, Enrique Gambra; Visual simulations of real multifocal lenses in a multi-channel Adaptive Optics system. Invest. Ophthalmol. Vis. Sci. 2017;58(8):1248.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : To compare through-focus (TF) optical & visual quality produced by real multifocal intraocular lenses with visual simulations using a Spatial Light Modulator (SLM) and temporal multiplexing with optotunable lenses (SimVis) in an Adaptive Optics Visual Simulator (AO).

Methods : A custom polychromatic AO system was used, which contained: a supercontinuum laser, a Hartmann-Shack wavefront sensor, an electromagnetic deformable mirror (DM), a double-pass retinal imaging channel (DP), phase-only reflective SLM, SimVis and phase plate channels, monochromatically illuminated psychophysical channel (DMD), Badal optometer and pupil monitor system. Two physical 0-D multifocal IOLs (trifocal diffractive –TriD- and bifocal non-rotationally symmetric refractive –BiR-) were projected on the eye’s pupil, and also mapped in the SLM (as a spatial phase map) and on SimVis (as a temporal profile). TF retinal images of an E-optotype were collected on an artificial eye (no aberrations, 5-mm pupil) with a CCD camera at the retina, and image correlation coefficient used as a metric to compare real IOL data with SLM & SimVis simulations. TF visual acuity (VA) was also obtained on 3 cyclopleged patients for the 3 conditions. Comparisons of TF quality on-bench and in patients were obtained in terms of RMS difference with the real IOL data as a reference.

Results : TF image correlation from on-bench measurements were 0.91/0.95/0.97 @far & 0.48/0.36/0.75 @+3.00D for BIR, and 0.94/0.90/0.99 @far & 0.27/0.33/0.32 @+3.50D for TriD for Real IOL/SimVis/SLM simulations. TF DP curves showed maximum values within 0.25 D for SLM and 0.50 D for SimVis with respect to Real IOLs . TF Visual Acuity curves (5 D range) in patients showed great individual similarity across simulations. Average RMS difference from Real IOL and simulated TF curves was 1.14 for BiR & 0.84 for TriD for SimVis, and 1.93 for BiR & 1.49 for TriD for SLM. VA values correlated highly between Real IOLs and SimVis (r=0.71 & r=0.46;p<0.05 across subjects for BIR and TriD) and Real IOLs and SLMs (r=0.46 & r=0.56;p<0.05 across subjects for BIR and TriD).

Conclusions : Visual simulations in an AO system capture to a large extent the optical and visual performance obtained with real IOLs, both in absolute values and the shape of TF curves when compared on the same individual patients. Visual Simulators are useful programmable tools to predict visual performance with multifocal IOLs.