June 2017
Volume 58, Issue 8
Open Access
ARVO Annual Meeting Abstract  |   June 2017
Use of a Computer-based Critical Flicker Fusion Test Discriminates between Young, Old, and Dry AMD Patients
Author Affiliations & Notes
  • Connie Slocum
    Ora, Inc, Andover, Massachusetts, United States
  • Keith Jeffrey Lane
    Ora, Inc, Andover, Massachusetts, United States
  • John David Rodriguez
    Ora, Inc, Andover, Massachusetts, United States
  • Aron Shapiro
    Ora, Inc, Andover, Massachusetts, United States
  • Mark Abelson
    Ora, Inc, Andover, Massachusetts, United States
  • David Hollander
    Ora, Inc, Andover, Massachusetts, United States
  • Footnotes
    Commercial Relationships   Connie Slocum, Ora, Inc. (E); Keith Lane, Ora, Inc. (E); John Rodriguez, Ora, Inc. (E); Aron Shapiro, Ora, Inc. (E); Mark Abelson, Ora, Inc. (E); David Hollander, Ora, Inc. (E)
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science June 2017, Vol.58, 2347. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Connie Slocum, Keith Jeffrey Lane, John David Rodriguez, Aron Shapiro, Mark Abelson, David Hollander; Use of a Computer-based Critical Flicker Fusion Test Discriminates between Young, Old, and Dry AMD Patients
      . Invest. Ophthalmol. Vis. Sci. 2017;58(8):2347.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : We have developed a simplified computer-based critical flicker fusion (CFF) test to rapidly assess visual function in a patient population for implementation in clinical trials. The test utilizes the PsychoPy toolkit, a software library written in the Python language, which is specifically designed for use in visual psychophysics. The aim of this study was to validate the computer-based CFF test by comparing differences in CFF scores between younger and older normal subjects and subjects with dry AMD.

Methods : This study enrolled 23 normal subjects with a mean (SD) age of 44.7 (9) years, 17 older normal subjects with a mean (SD) age of 74.5 (4) years, and 9 subjects with dry AMD with a mean (SD) age of 77.8 (6.8) years. Dry AMD was defined by signs of pigmentary changes, mottling and/or the presence of some drusen, and a potential acuity measurement (PAM) between 20/30 and 20/80. After a 45-minute dark adaptation period, CFF was measured twice in each eye, 5 minutes apart, with stimulus presented using a staircase design with test frequencies set at 20, 24, 30, 40 and 60 Hz. The stimulus used a single circular blob (Goldmann size 5) presented centrally.

Results : Older subjects had reduced CFF relative to younger subjects with 42.9% of eyes in younger subjects perceiving flicker frequencies greater than 30 Hz compared 21.2% of eyes in older subjects. CFF scores for dry AMD subjects showed a reduction in CFF relative to older normal subjects, with 31% of dry AMD subjects having a CFF threshold of 24 Hz relative to 6% for older normal subjects.

Conclusions : A computer-based CFF test may be a valuable tool to discriminate patient populations and may be readily employed for multi-centered trials.