July 2018
Volume 59, Issue 9
Open Access
ARVO Annual Meeting Abstract  |   July 2018
Clinical applicability of a model eye for intraocular pressure measurement
Author Affiliations & Notes
  • Seung Hyen Lee
    Department of Ophthalmology, Bundang Jesaeng General Hospital, Daejin Medical Center, Seongnam, Korea (the Republic of)
  • Han Saem Cho
    Korea Research Institute of Standards and Science , Daejeon, Korea (the Republic of)
  • Heung Soon Lee
    Korea Research Institute of Standards and Science , Daejeon, Korea (the Republic of)
  • Tae-Woo Kim
    Department of Ophthalmology, Seoul National University Bundang Hospital, Seoul National University, Seongnam, Korea (the Republic of)
  • Eun Ji Lee
    Department of Ophthalmology, Seoul National University Bundang Hospital, Seoul National University, Seongnam, Korea (the Republic of)
  • Sae Chae Jeoung
    Korea Research Institute of Standards and Science , Daejeon, Korea (the Republic of)
  • Footnotes
    Commercial Relationships   Seung Hyen Lee, None; Han Saem Cho, None; Heung Soon Lee, None; Tae-Woo Kim, None; Eun Ji Lee, None; Sae Chae Jeoung, None
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science July 2018, Vol.59, 2698. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Seung Hyen Lee, Han Saem Cho, Heung Soon Lee, Tae-Woo Kim, Eun Ji Lee, Sae Chae Jeoung; Clinical applicability of a model eye for intraocular pressure measurement. Invest. Ophthalmol. Vis. Sci. 2018;59(9):2698.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : Given that clinical significance of intraocular pressure (IOP), accurate IOP measurements are crucial. However, measurement of IOP is affected by corneal properties such as thickness, curvature, and biomechanical properties. To derive the quantitative relationship between corneal variables and IOP, it is valuable to create a theoretical model that represents these various properties of the cornea. We have constructed optically transparent artificial eye phantoms, which have closely similar to a human eye. The purpose of this study is to evaluate the clinical applicability of artificial eye by understanding and quantifying the IOP measurement.

Methods : The artificial model eye has made of polydimethylsiloxane (PDMS) and its inside is filled with glycerol solution. We developed three different shapes of model eye to reflect the variation in corneal diameter and radius of curvature (Fig. 1C). Corneal properties (i.e., elasticity) were varied according to the formulation of PDMS (Young’s modulus: 1.7 MPa, 0.7 Mpa, and 0.4 MPa) and corneal thickness was differed by varying the concentration of ethylene glycol. The effect of each variable on the measurement of IOP was examined quantitatively using Goldmann applanation tonometry.

Results : The IOP of the model eye showed significant positive correlation with corneal thickness in all shapes of model eye (all P < 0.001). The range of the IOP changed according to Young’s modulus of model eye. (12 to 80 mmHg, 1 to 80 mmHg, and 1 to 32 mmHg in model eyes with 1.7 MPa, 0.7MPa, and 0.4 MPa, respectively, Fig. 1D-F). Relationship between the IOP and thickness differed depending on the Young’s modulus of the model eye (Fig. 1D-F).

Conclusions : The IOP of the developed artificial eyeball was successfully measured by Goldmann applanation tonometer in a similar manner to a real human eye. This finding suggests that the artificial model eye may have a value as an independent, reproducible sample that allows comparison of tonometers.

This is an abstract that was submitted for the 2018 ARVO Annual Meeting, held in Honolulu, Hawaii, April 29 - May 3, 2018.

 

(A) Model eye, (B) model eye aligned on the slip lamp,. (C) Schematic presentation of three types of eye shape. Correlation between IOP and thickness in eyes with Young’s modulus of 1.7 MPa (D), 0.7 MPa (E), and 0.4 MPa (F). (D-F) The pink dotted line indicates the pressure contributed by corneal properties.

(A) Model eye, (B) model eye aligned on the slip lamp,. (C) Schematic presentation of three types of eye shape. Correlation between IOP and thickness in eyes with Young’s modulus of 1.7 MPa (D), 0.7 MPa (E), and 0.4 MPa (F). (D-F) The pink dotted line indicates the pressure contributed by corneal properties.

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×