July 2018
Volume 59, Issue 9
Open Access
ARVO Annual Meeting Abstract  |   July 2018
Donor Cornea Quality Preserved in two different Media: Eusol-C® and Optisol-GS®
Author Affiliations & Notes
  • Livia Andrade Freire
    Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, SP, Brazil
  • Pedro Henrique pinheiro vizibelli Chaves
    Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, SP, Brazil
  • Fabio Antonio Del Picchia de Araujo Nogueira
    Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, SP, Brazil
  • Davi Chen Wu
    Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, SP, Brazil
  • Pedro Augusto de Andrade Poletto
    Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, SP, Brazil
  • Adamo Lui Netto
    Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, SP, Brazil
  • Jasmine Masuzaki Wong
    Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, SP, Brazil
  • Eva Mackus
    Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, SP, Brazil
  • Richard Y Hida
    Irmandade da Santa Casa de Misericordia de Sao Paulo, Sao Paulo, SP, Brazil
  • Footnotes
    Commercial Relationships   Livia Freire, None; Pedro Chaves, None; Fabio Nogueira, None; Davi Chen Wu, None; Pedro Poletto, None; Adamo Netto, None; Jasmine Wong, None; Eva Mackus, None; Richard Hida, None
  • Footnotes
    Support  none
Investigative Ophthalmology & Visual Science July 2018, Vol.59, 4332. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Livia Andrade Freire, Pedro Henrique pinheiro vizibelli Chaves, Fabio Antonio Del Picchia de Araujo Nogueira, Davi Chen Wu, Pedro Augusto de Andrade Poletto, Adamo Lui Netto, Jasmine Masuzaki Wong, Eva Mackus, Richard Y Hida; Donor Cornea Quality Preserved in two different Media: Eusol-C® and Optisol-GS®. Invest. Ophthalmol. Vis. Sci. 2018;59(9):4332.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : There are different kinds of donor cornea preservation media. There are still some controversies in which preservation media has a better capacity of preservation. The purpose of this study is to compare the quality of donor cornea preserved in two different media: Eusol-C® and Optisol-GS®.

Methods : A cross-sectional study was performed using patient records of 1062 donor corneas from our local Eye Bank (Santa Casa de Misericordia de São Paulo, Brazil) from 2013 to 2016. Epithelial exposure, epithelial defect, Descemet folds, stromal striae, and stromal edema were scored by an experienced ophthalmologist using slit lamp. These quality measurements were scored as: 0 - excellent; 1- good; 2- regular; 3- bad; 4- unacceptable. Endothelial cell density was measured using eye bank specular microscope (EB-10, Konan, Japan). Data from optical and tectonic graft preserved in Eusol-C® and Optisol-GS® were compared using non-parametric Mann-Whitney test.

Results : Among the 1062 corneas evaluated in the study, 75.9% were preserved with Optisol and 24.1% with Eusol. For optical grafts, we could observe statistical significance in Descemet fold, stromal striae and edema. For tectonic grafts, we could observe statistical significance in epithelial defect, Descemet fold, and stromal and edema. No statistical significance was observed for endothelial density in both groups in neither preservation media (Figure 1).

Conclusions : Donor Corneas preserved with Optisol showed better quality compared to the ones preserved with Eusol.

This is an abstract that was submitted for the 2018 ARVO Annual Meeting, held in Honolulu, Hawaii, April 29 - May 3, 2018.

 

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×