July 2019
Volume 60, Issue 9
Open Access
ARVO Annual Meeting Abstract  |   July 2019
Influence of the Stiles-Crawford effect of the first kind on visual acuity for decentered pupils
Author Affiliations & Notes
  • Alessandra Marie Carmichael Martins
    School of Physics, University College Dublin, Dublin, Dublin, Ireland
  • Maria Vinas
    Instituto de Opctica, CSIC, Madrid, Madrid, Spain
  • Ana Gonzalez-Ramos
    Instituto de Opctica, CSIC, Madrid, Madrid, Spain
  • Clara Benedi-Garcia
    Instituto de Opctica, CSIC, Madrid, Madrid, Spain
  • Carlos Dorronsoro
    Instituto de Opctica, CSIC, Madrid, Madrid, Spain
  • Susana Marcos
    Instituto de Opctica, CSIC, Madrid, Madrid, Spain
  • Brian Vohnsen
    School of Physics, University College Dublin, Dublin, Dublin, Ireland
  • Footnotes
    Commercial Relationships   Alessandra Marie Carmichael Martins, None; Maria Vinas, None; Ana Gonzalez-Ramos, None; Clara Benedi-Garcia, None; Carlos Dorronsoro, None; Susana Marcos, None; Brian Vohnsen, None
  • Footnotes
    Support  H2020 ITN MyFUN grant agreement no. 675137
Investigative Ophthalmology & Visual Science July 2019, Vol.60, 5943. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Alessandra Marie Carmichael Martins, Maria Vinas, Ana Gonzalez-Ramos, Clara Benedi-Garcia, Carlos Dorronsoro, Susana Marcos, Brian Vohnsen; Influence of the Stiles-Crawford effect of the first kind on visual acuity for decentered pupils. Invest. Ophthalmol. Vis. Sci. 2019;60(9):5943.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : The purpose of this study is to measure the Stiles-Crawford effect of the first kind (SCE-I) under normal visual conditions (Newtonian view) using a horizontally-decentered small pupil rather than the commonly used Maxwellian view and analyze the potential impact of the SCE-I on the corresponding off-centered visual quality.

Methods : A spatial light modulator (PLUTO, Holoeye) is used to sequentially create horizontally displaced aperture masks of 1.5mm in a monocular viewing system across a 6.5mm pupil size. Measurements were performed in 4 subjects (OD, dilated pupil, ages:25-48; SE: 0 to -5.75D). The SCE-I was measured psychophysically, by the subjects adjusting the brightness of a 1.8-deg natural stimulus on the retina (using a liquid crystal variable attenuator for intensity control, Meadowlark) alternating at 1Hz, with a centered reference stimulus of the same size. Visual acuity (VA) was measured using a tumbling E test (8AFC QUEST algorithm), in natural viewing for 1.5 mm pupils. A control VA was obtained under natural SCE for a 6-mm pupil. A total of 4 sets of 7 displaced apertures were performed for all subjects. Finally, the VA test was performed a second time, accounting for these variations with the variable attenuator, such that subjects perceived the same brightness for each aperture location.

Results : A slight variation in the SCE-I directionality parameter was found in Newtonian view compared to Maxwellian view within subject intervariability. Monocular decimal VA for 6-mm pupil was 0.62±0.02 on average and increased by 39% for a centered 1.5mm pupil. A decay in VA between 50-70% was observed for a horizontal displacement of 2.5mm nasal and 20-40% when displaced temporally. Correction of the SCE-I produced an average difference of VA up to 30%. In a 1.6mm nasal and 2.5mm temporal decentration range, the difference in VA with and without SCE correction was negligible (<8%) in subjects with large ocular aberrations (RMS wavefront error=0.87µm). In subjects with lower aberrations (RMS<0.4µm) statistical differences in VA were found between data obtained with and without SCE-I compensation.

Conclusions : The VA is noticeably reduced with decentered small pupils, mostly due to an increased impact of ocular aberrations. The reduced differences between the SCE-I corrected and uncorrected VA results indicate a small effect of the SCE-I in visual degradation with decentered pupils.

This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019.

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×