July 2019
Volume 60, Issue 9
Open Access
ARVO Annual Meeting Abstract  |   July 2019
Perceptual and physical limits to temporal multiplexing simulation of multifocal corrections
Author Affiliations & Notes
  • Carlos Dorronsoro
    INSTITUTO DE OPTICA (IO-CSIC), Madrid, Spain
    Center for Perceptual Systems, University of Texas at Austin, Austin, Texas, United States
  • Victor Rodríguez-Lopez
    INSTITUTO DE OPTICA (IO-CSIC), Madrid, Spain
  • Xoana Barcala
    INSTITUTO DE OPTICA (IO-CSIC), Madrid, Spain
    2Eyes Vision, Spain
  • enrique Gambra
    2Eyes Vision, Spain
  • Vyas Akondi
    INSTITUTO DE OPTICA (IO-CSIC), Madrid, Spain
  • Lucie Sawides
    2Eyes Vision, Spain
  • Yassine Marrakchi
    2Eyes Vision, Spain
  • Eduardo Lage
    Universidad Autonoma de Madrid, Spain
  • Wilson S Geisler
    Center for Perceptual Systems, University of Texas at Austin, Austin, Texas, United States
  • Susana Marcos
    INSTITUTO DE OPTICA (IO-CSIC), Madrid, Spain
  • Footnotes
    Commercial Relationships   Carlos Dorronsoro, 2Eyes Vision (I), P201730854 (P), PCT/ES2010/070218 (P), PCT/ES2014/070725 (P), PCT/ES2016/070673 (P); Victor Rodríguez-Lopez, P201730854 (P); Xoana Barcala, 2Eyes Vision (E), P201730854 (P); enrique Gambra, 2Eyes Vision (I), 2Eyes Vision (E), P201730854 (P); Vyas Akondi, 2Eyes Vision (I); Lucie Sawides, 2Eyes Vision (E), 2Eyes Vision (I); Yassine Marrakchi, 2Eyes Vision (E); Eduardo Lage, 2Eyes Vision (I); Wilson Geisler, None; Susana Marcos, 2Eyes Vision (I), P201730854 (P), PCT/2014ES/070725 (P), PCT/ES2010/070218 (P), PCT/ES2016/070673 (P)
  • Footnotes
    Support  Spanish Government RyC-2016-21125, PTQ-15-07432, FPU17/02760, FIS2014-56643-R, FIS2017-84753-R and ISCIII-DTS16-00127, S Madariaga MECD PRX16/00154 + Fulbright CIES FMECD-ST-2016; EU H2020 SME IA GA-739882; EIT Health; ERC-2011-AdC 294099; CAM IND2017/BMD-7670; CAM and Marie Curie Action EU FP7/2007-2013 COFUND 291820
Investigative Ophthalmology & Visual Science July 2019, Vol.60, 6465. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Carlos Dorronsoro, Victor Rodríguez-Lopez, Xoana Barcala, enrique Gambra, Vyas Akondi, Lucie Sawides, Yassine Marrakchi, Eduardo Lage, Wilson S Geisler, Susana Marcos; Perceptual and physical limits to temporal multiplexing simulation of multifocal corrections. Invest. Ophthalmol. Vis. Sci. 2019;60(9):6465.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : Recent simultaneous vision simulators (SimVis) rely on the principle of temporal multiplexing of optotunable lenses (TL): Image components from different foci are superimposed to match the thru-focus optical quality of specific multifocal patterns. If sufficiently fast, the retinal images appear static. The temporal physical and perceptual aspects of temporal multiplexing are experimentally evaluated.

Methods : A custom electronic driver is used to address temporal patterns of optical power onto TLs. Physical limitations (rise time, temporal frequency response, repeatability) of 8 TLs (Optotune) were measured in a custom high-speed focimeter (3800fps). An iterative method was used to compensate dynamic effects (due to inertia, damping). To test the perceptual limitations, high-contrast high-luminance E letters (0.5-2deg) and 2deg natural images were viewed under temporal multiplexing (SimVis 2EyesVision) with square-wave power variations of defocus amplitude (0-3.5D) at varying temporal frequencies (1-500Hz). Just noticeable periodic blur changes were measured on 4 subjects to provide, for the first time, the Defocus Temporal Sensitivity Function (DTSF, perceptual thresholds of defocus amplitude vs temporal frequency), and the Defocus Flicker Fusion (DFF, cut-off frequency for sensitivity to periodic changes in defocus), using a 2AFC task implemented with a QUEST algorithm.

Results : The static responses of TLs were linear with input signal (R2>0.99). The dynamic response was linear and highly repetitive (RMSE 0.05D). The settling time varied from 8 to 100 ms across TLs (rise time 1.3-46 ms), with a velocity up to 1.3D/ms. The measured distortions in the temporal response of the fastest TL (RMSE 0.23D at 50Hz) were compensated to improve response fidelity (RMSE 0.07D). The amplitude of the TL response was not reduced for frequencies below 100Hz. Perceptually, DTSF was measured with low uncertainty (STD 0.05D), with similar trends across subjects and stimuli. Maximum DTSF (0.1-0.22D) occurred at ~10Hz. DTSF was <1D for frequencies<30Hz. We found DFF=40Hz.

Conclusions : Temporal Multiplexing is compatible with the physical limits of TLs and with the perceptual limits of the subjects. Measurements of the DTSF in subjects revealed that defocus variations at frequencies >40Hz are not perceived. This bandwidth can be achieved by commercial TLs allowing multifocal visual simulators free of temporal artifacts.