ARVO Annual Meeting Abstract  |   July 2019
Correction of artifacts from misregistered B-scans in orthogonally scanned and registered OCT angiography
Author Affiliations & Notes
  • Stefan B Ploner
    Pattern Recognition Lab, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany
    Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts, United States
  • Julia Schottenhamml
    Pattern Recognition Lab, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany
    Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts, United States
  • Eric Moult
    Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts, United States
  • Lennart Husvogt
    Pattern Recognition Lab, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany
    Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts, United States
  • A. Yasin Alibhai
    New England Eye Center, Tufts Medical Center, Boston, Massachusetts, United States
  • Nadia K Waheed
    New England Eye Center, Tufts Medical Center, Boston, Massachusetts, United States
  • Jay S Duker
    New England Eye Center, Tufts Medical Center, Boston, Massachusetts, United States
  • James G Fujimoto
    Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts, United States
  • Andreas K Maier
    Pattern Recognition Lab, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany
  • Footnotes
    Commercial Relationships   Stefan Ploner, IP related to VISTA-OCTA (P); Julia Schottenhamml, None; Eric Moult, IP related to VISTA-OCTA (P); Lennart Husvogt, None; A. Yasin Alibhai, None; Nadia Waheed, Carl Zeiss Meditec (F), Heidelberg Engineering (F), MVRF (F), Nidek (F), Optovue (C), Topcon (F); Jay Duker, Carl Zeiss Meditec (F), Carl Zeiss Meditec (C), Optovue (F), Optovue (C), Topcon (F), Topcon (C); James Fujimoto, Carl Zeiss Meditec (P), IP related to VISTA-OCTA (P), Optovue (P), Optovue (I), Optovue (C), Topcon (F); Andreas Maier, None
  • Footnotes
    Support  NIH 5-R01-EY011289-31, AFOSR FA9550-15-1-0473, Macula Vision Research Foundation (MVRF), Champalimaud Vision Award, Beckman-Argyros Award in Vision Research, Massachusetts Lions Clubs
Investigative Ophthalmology & Visual Science July 2019, Vol.60, 3097. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Stefan B Ploner, Julia Schottenhamml, Eric Moult, Lennart Husvogt, A. Yasin Alibhai, Nadia K Waheed, Jay S Duker, James G Fujimoto, Andreas K Maier; Correction of artifacts from misregistered B-scans in orthogonally scanned and registered OCT angiography. Invest. Ophthalmol. Vis. Sci. 2019;60(9):3097.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : While individual volumetric optical coherence tomography (OCT) scans suffer from distortion especially along the slowly scanned transverse axis, registration enables merging of two orthogonally oriented B-scans into one averaged volume with corrected distortion and reduced noise. However, registration errors can occur, which appear as blurred or duplicated vessels in en-face OCT angiography (OCTA) images. We present a fully automatic method that excludes artifacts and locally smooths resulting en-face images to achieve a uniform noise level. Noise non-uniformity emerges from differing numbers of averaged samples. This occurs when misregistrations or saccadic OCTA B-scans are excluded or due to varying depth of projected layers in en-face images. Uniform noise is critical for subsequent analysis algorithms to produce consistent results throughout the image.

Methods : Two orthogonally scanned OCT volumes are registered and individual en-face OCTA images are computed. By design, errors in registration occur along B-scans, thus they extend along horizontal or vertical lines in the en-face images. As vessels do not coincide within misregistrations, these lines are detected via their high difference between the en-face images. The scan with B-scan orientation along the line can be identified as the one containing the misregistration and only that scan's B-scan is excluded, while the valid data in the other scan is preserved.
To compensate for locally increased noise due to smaller numbers of averaged samples, adaptive Gaussian smoothing is applied. The standard deviation is controlled locally by the number of excluded scans and the remaining scans' sampling densities and projected layers' thickness, such that the total contribution of samples per pixel is kept uniform. The method was evaluated on 8 healthy eyes and 6 eyes with various pathologies.

Results : Figure 1 shows the classification performance, Figure 2 compares merged images.

Conclusions : The number of artifacts in orthogonal scan based OCTA volume registration was reduced while preventing noise non-uniformity due to varying numbers of averaged samples per pixel.

This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019.

 

Leave-one-out cross-validation normalized confusion matrix.

Leave-one-out cross-validation normalized confusion matrix.

 

Vertically scanned OCTA image (A) and merged images w/o (B) and w/ automatic exclusion (C) of B-scans. Misregistrations at arrows. (D) Adaptively smoothed result. (E/F) Zooms into (C/D). Increased noise between lines.

Vertically scanned OCTA image (A) and merged images w/o (B) and w/ automatic exclusion (C) of B-scans. Misregistrations at arrows. (D) Adaptively smoothed result. (E/F) Zooms into (C/D). Increased noise between lines.

×
×